Marshall electronic V-R231-IMD-HDSDI manual Service Submenu, Tally Source, IMD Tally Mode

Models: V-R231-IMD-HDSDI

1 23
Download 23 pages 21.3 Kb
Page 20
Image 20

On-Screen Menu (continued)

IMD CONFIGURATION SUBMENU (continued)

Tally Source

The V-R231-IMD-HDSDI tally (OSD and LED) can be controlled in a variety of different ways. Use the Tally Source setting to choose how tally is controlled:

Standard

Use the Standard setting to control tally via contact closure on the HD-15 tally interface.

Image Video HW

Use the Image Video HW setting to control Image Video tally states via contact closure on the HD-15 tally interface. Contact closure of the Red pin corresponds to Image Video Tally 1, and the Green pin maps to Image Video Tally 2. Contact closure (ground) corresponds to a LOW state, and open circuit corresponds to a HIGH state. This mode requires the IMD Tally Mode parameter to be set. Consult Image Video documentation for further information.

Image Video 422

Use the Image Video 422 setting to control Image Video tally states via the Image Video serial protocol. LED and OSD tally will be disabled in this mode, as Image Video tally states are manifested in the text color and other parameters. This mode requires the IMD Tally Mode parameter to be set. Consult Image Video documentation for further information.

Standard + IV422

Use the Image Video 422 setting to control Image Video tally states via the Image Video serial protocol, while controlling LED and OSD tally using contact closure on the HD-15 tally interface. This mode requires the IMD Tally Mode parameter to be set. Consult Image Video documentation for further information.

TSL/Marshall 422

Use the TSL/Marshall 422 setting to control OSD and LED tally via the TSL or Marshall serial protocols.

IMD Tally Mode

Use this setting when using Image Video tally control. Choose one of the following settings, in conjunction with the Image Video controlling device. T1, T2, T1T2, T2T1, T1-,T2-,T1T2-,T2T1-. Consult Image Video documentation for further information.

SERVICE SUBMENU

Overview

The Service submenu displays the status of the serial interface, for troubleshooting or debugging purposes only. Contact Marshall Electronics for further information. The following information is displayed:

• Serial Characters

Rx:

Total number of characters received by the UART

 

Tx:

Total number of characters transmitted by the UART

• Serial Errors

P:

Number of parity errors

 

F:

Number of framing errors

 

O:

Number of FIFO overrun errors

• Packets

Rec:

Number of packets received

 

Exe:

Packets Executed

• Packet Errors

CRC:

Number of packets that failed CRC check

 

Err:

Number of other packet errors

• Last Command

R:

Last command received

 

E:

Last command executed

• Software State

State:

000:000 1010111 (correct value)

21