Drain Pan and Light Shield Removal

Drain Pan and Light Shield Removal

Light Shield

Drain Pan

SERVICE INSTRUCTIONS

OPERATION CONDITIONS AND PRESSURES

To remove the drain pan, remove screws along the front face of the drain pan. Lift the rear of the pan up and out of the drain trough. Slide pan towards you and out.

Reverse procedure to install.

To remove the light shield, remove screws along the front face of the light shield. Pull the light shield towards you and out. Reverse procedure to reinstall.

With room ambient temperature of +80 oF and cold cabinet (unit cycling on control):

Suction pressure – 5 to 9 psig.

Head pressure – 210 to 260 psig.

Typical operating pressures for a properly charged unit operating at 0°F or lower box temperature, check pressures immediately before normal off cycle expect a tolerance of ± 5 psig high side, and ±1 psig low side.

11

Page 11
Image 11
Master Bilt GT-40, GT-30 manual Drain Pan and Light Shield Removal, Light Shield Drain Pan, Service Instructions