Master Lock BR150CE owner manual Specifications

Models: BR150CE

1 20
Download 20 pages 55.35 Kb
Page 15
Image 15
SPECIFICATIONS

Fan

IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch.

1.Remove upper shell (see page 10).

2.Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft.

3.Slip fan off motor shaft.

4.Clean fan using a soft cloth moistened with kerosene or solvent.

5.Dry fan thoroughly.

6.Replace fan on motor shaft. Place fan hub flush with end of motor shaft (see Figure 19).

7.Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds/ 4.5-5.6 n-m).

8.Replace fan guard and upper shell.

SPECIFICATIONS

Setscrew

Fan

Motor

Shaft

Figure 18 - Fan, Motor Shaft, and Setscrew Location

Fan

Flush

Motor

Shaft

Setscrew

Figure 19 - Fan Cross Section

Output Rating (Btu/Hr)

150,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity

 

(U.S. Gal./Liters)

13.5/51.1

Fuel Consumption

 

(Gal. Per Hr./Liters Per Hr.)

1.1/4.1

Electric Requirements

220 V/50 Hz

Amperage (Normal Run)

1.2

Hot Air Output (CFM/CMM)

500/14.2

RPM

2850

15

102384