Master Lock BR150CE Air Output, Air Intake, and Lint Filters, Pump Pressure Adjustment

Models: BR150CE

1 20
Download 20 pages 55.35 Kb
Page 12
Image 12
Air Output, Air Intake, and Lint Filters

Air Output, Air Intake, and Lint Filters

1.Remove upper shell (see page 10).

2.Remove filter end cover screws using 5/16" nut- driver.

3.Remove filter end cover.

4.Replace air output and lint filters.

5.Wash or replace air intake filter (see Preventative Maintenance Schedule, page 8).

6.Replace filter end cover.

7.Replace fan guard and upper shell.

IMPORTANT: Do not oil filters

Pump Pressure

Adjustment

1.Remove pressure gauge plug from filter end cover.

2.Install accessory pressure gauge (part number HA1180).

3.Start heater (see Operation, page 7). Allow motor to reach full speed.

4.Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. See specifications at right for correct pressure for each model.

5.Remove pressure gauge. Replace pressure gauge plug in filter end cover.

12

Air Intake Filter

Filter End

Fan Guard

Cover

 

Lint Filter

Air Output

Filter

Figure 10 - Air Output, Air Intake, and Lint Filters

Relief Valve

Location

Pressure

Gauge Plug

Figure 11 - Pressure Gauge Plug Removal

 

PUMP

Pressure

MODEL

PRESSURE

Gauge

150,000 Btu/Hr

4.8 PSI

 

Figure 12 - Adjusting Pump Pressure

102384