OWNER’S MANUAL

OPERATION

Continued

Model MGH10000 also has a 120/240V, 50-amp receptacle (see Figure 15).

Model HWI3000 has only the 120V, 20- amp duplex receptacle.

Models MGH3000 and MGH3000PR have only the 120V, 15-amp GFCI duplex receptacle.

120V, 15-Amp GFCI Duplex

 

120V, 15-Amp Duplex

 

 

120/240V, 20 or

 

 

30-Amp Twist-Lock

120

VOLTS

 

 

 

 

 

 

 

 

 

 

RESET

 

 

 

 

 

TEST

 

 

 

 

 

120

 

 

 

 

 

ONLY

 

 

 

 

 

 

 

 

120

 

 

 

 

EN

240V

 

 

 

00

M

 

 

 

 

 

 

H

00

 

 

 

OU

00

 

 

 

RS

05

R

 

 

 

 

1

ES

 

 

 

 

/10

ET

120V, 30-Amp

 

 

 

RE

Twist-Lock

 

 

 

SET

 

 

 

 

POWER CORD AND PLUG REQUIREMENTS

120V, 30-amp twist-lock receptacle

NEMA L5-30P plug

Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock receptacle

NEMA L14-20P (20-amp) or L14-30P (30-amp) plug

Four-wire, 20-amp or 30-amp cord

120/240V, 50-amp receptacle

NEMA L14-50P

Four-wire, 50-amp cord

120/240 Volt

 

 

 

 

20 Amp

 

Neutral

 

 

 

 

 

 

120V

120V

 

Ground

X

 

w

L14-20P

Y

X

(Green)

(Hot)

 

G

Plug

 

 

Ground

 

Y

W

 

 

 

(Neutral)

 

 

 

(Hot)

 

 

 

 

 

 

 

PRESTART

Operate generator on a firm, dry, and clean surface. The surface must be level. Protect generator from heavy dust, sand, dirt, rain, or snow. Do not locate generator near stand- ing water and snow. Make sure area is well- vented.

WARNING: Only responsible adults should use generator. Never let anyone operate genera- tor without proper instructions.

Note: If oil level is too low, oil alert system will keep engine from starting (see Oil Alert System, page 6). Make sure oil level is full before starting. See Engine Oil, page 7.

Before starting the engine, disconnect all electric loads from generator.

STARTING

IMPORTANT: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle. Preset position lets en- gine run at 3600 RPM under load. The engine must maintain 3600 RPM for gen- erator to create correct voltage. Running engine at lower speeds will damage genera-

R

240

 

ESET

VO

 

 

LTS

RESET

 

RESET

 

 

 

 

RESET

120/240 Volt

20 and 30

Amp

Ground (Green)

Y (Hot)

Neutral 120V 120V

L14-20P

wPlug

Y X

GGround L14-50P

Plug

X

Ground

Y

G

X

(Hot)

Neutral

 

w

 

120V

120V

 

 

 

 

 

 

 

 

 

 

120V

 

120V

w

Y X Neutral

G

WL14-30P

(Neutral)Plug Ground

tor and powered items.

IMPORTANT: Never start generator with electrical loads connected. Start engine be- fore adding electrical loads.

1.

Make sure gasoline tank is full. See

 

Fuel, page 7 for fuel information.

2.

Move fuel valve lever to the ON posi-

 

tion except on model MGH3000PR

 

(see Figure 17).

3.

Move choke lever fully to the left for

Figure 16 - Cord and Plug Configurations

120/240V, 50-Amp

(Model MGH10000 only)

Figure 15 - Receptacle Locations

all models except MGH3000PR and

MGH10000 (see Figure 17). Pull

choke rod for model MGH3000PR or

choke button for model MGH10000

out (see Figures 18 and 19). This

closes the choke.

Note: You may not need to close

choke if engine is warm or air tem-

perature is high.

Continued

105420

11