R

PORTABLE GASOLINE GENERATORS

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual and the engine owner’s manual carefully. Become famil- iar with this generator before try- ing to operate or service it. Know its uses, limitations, and any haz- ards involved. Improper use of generator can cause severe in- jury or death from explosion, fire, burns, electrical shock, or car- bon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Engine exhaust contains poisonous carbon monoxide gas. Overexposure will cause loss of consciousness and will lead to death. Use only in well-vented areas. Make sure area has plenty of free-moving, fresh, outside air. Never run generator in an enclosed or confined area. Never run generator inside occupied building.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and nausea. If you have these signs, get fresh air at once! Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this generator.

Safety information appears throughout these instructions. Pay close attention to them. Below are definitions for the safety infor- mation listed throughout this manual.

DANGER:indicatesahazardwhichwillcause severe personal injury, death, or substantial property damage if you ignore warning.

WARNING: indicates a hazard which can causeseverepersonalinjury,death,orsubstan- tial property damage if you ignore warning.

CAUTION: indicates a hazard which will or can cause minor personal injury or prop- erty damage if you ignore warning.

1.Gasoline presents a hazard of fire or ex- plosion. Gasoline is flammable. Its va- por is explosive.

Keep fuel out of children’s reach.

Refuel generator in a well-vented area. Do not fill fuel tank in the dark. Do not refuel while engine is run- ning. Unhook all electrical loads and shut off engine before refueling.

Do not overfill fuel tank. Always al- low room for fuel to expand. If you overfill tank, fuel can overflow onto hot generator. This can cause fire or explosion. After refueling, tightly close fuel tank cap.

Do not spill fuel. Fuel or fuel vapor may ignite. If fuel spills, make sure area is dry before starting engine.

Never smoke in refueling area. Never allow open flames or sparks in area.

Store fuel in approved container. Store fuel in a well-vented area free of open flames or sparks.

2.Guard against fire hazard. Keep opera- tion area well-vented. Keep generator at least three feet away from any ob- ject. Do not place flammable objects near generator.

Do not use generator where flam- mable vapors are present. Some va- pors are heavier than air. These va- pors settle in low-lying places.

Do not use generator in enclosed spaces. This includes motor home or RV generator compartments.

3.Guard against electric shock. Generator produces high voltage. This high voltage can cause severe electric shock. Only re- sponsible adults should use generator.

Properly ground generator before starting.

Never let anyone operate or service generator without proper instruc- tions.

Avoid contact with live terminals or bare wires.

Do not use generator outdoors in rain or snow.

Do not use generator near standing water or snow.

Do not use if generator is wet or damp.

Do not use generator in highly con- ductive areas. These areas include metal decking and steelwork.

Only use grounded extension cords.

Do not use any worn or damaged electric cords. Electric shock or dam- age to generator may result.

Do not wear damp clothing or wet shoes when using generator.

4.Guard against burns. Hot engine parts can cause severe injury. Use caution and remain alert when using generator.

Keep children and animals away from generator while it is running or hot.

Keep all covers and shields in place. Keep them tightly secured.

The muffler becomes very hot dur- ing operation. The muffler remains hot for a while after shutdown. Do not touch muffler while it is hot. Do not let muffler touch anything flam- mable. Let engine cool before trans- porting or storing.

5.Have standby installation to home or building performed by a licensed elec- trician. Do not let anyone else wire into a utility circuit. Personal injury, equip- ment damage, or damage to home could occur.

6.Never connect generator to any exist- ing electrical circuits. The generator output will back-feed into the utility power line. This may electrocute a power company line repair person. Also, if generator is powering electri- cal circuits, the chance of an electrical fire exists.

7.Battery gives off explosive gases. Keep sparks, flames, and cigarettes away. Do not remove or install battery cables when engine is cranking or running. Only service or use battery in a well- vented area.

8.Battery contains sulfuric acid. Battery acid is poisonous if swallowed. Con- tact with skin or eyes may cause severe burns. Do not tilt generator with bat- tery installed. Tilting could cause bat- tery acid to spill. Wear protective cloth- ing and face shield when servicing. Keep out of children’s reach.

2

105420

Page 2
Image 2
Master Lock MGH3000PR, MGH4000C installation manual Portable Gasoline Generators, Safety Information

MGH3000PR, MGH4000C specifications

The Master Lock MGH4000C and MGH3000PR are two innovative locks, designed with cutting-edge technology to enhance security and provide convenience for users. Both models embody Master Lock's commitment to safety and reliability, making them popular choices for both personal and professional use.

The MGH4000C is a high-performance combination lock that features a sleek, modern design. One of its standout features is the Bluetooth connectivity, allowing users to lock and unlock their devices from a distance using their smartphones. This smart technology provides unprecedented convenience, eliminating the need for physical keys or remembering complex combinations. The lock can easily be managed through the Master Lock app, enabling users to grant access to others and track usage history with just a few taps on their smartphone.

In addition to Bluetooth functionality, the MGH4000C is built with a robust steel body and shackle, ensuring durability in various weather conditions. Its weather-resistant properties make it ideal for outdoor use, providing reliable security against theft. The lock is powered by a long-lasting battery, which can be easily replaced, ensuring that it remains operational even for extended periods.

The MGH3000PR, on the other hand, is a versatile dial combination lock known for its traditional appeal combined with advanced security features. This model utilizes a patented anti-shim technology that adds an extra layer of resistance against tampering and unauthorized access. The MGH3000PR is designed with a heavy-duty construct, making it suitable for lockers, storage units, and other applications requiring strong security standards.

One of the key features of the MGH3000PR is its easy-to-read combination dial, which allows users to quickly input their codes without hassle. The lock also comes with a resettable design, meaning users can set their own combinations for personalized security. This feature is crucial in ensuring that users have full control over who can access their belongings.

Both models reflect Master Lock's dedication to innovation, safety, and user-friendly functionality. With their unique features and robust designs, the MGH4000C and MGH3000PR cater to a wide range of security needs, whether for indoor or outdoor use, making them excellent investments for anyone seeking reliable protection for their valuables.