This generator is not large enough to power your entire home. Do not connect generator to any existing electrical circuits. Plug items directly into generator receptacles. Do not exceed amperage rating of receptacles. Only use grounded cords.

DANGER: Use only in well- vented areas. Make sure area has plenty of free-moving, fresh, out- side air. Never run generator in an enclosed or confined area. Never run generator inside occu- pied building. Engine exhaust contains poisonous carbon mon- oxide gas. Overexposure will cause loss of consciousness and will lead to death.

DANGER: Never connect gen- erator to any existing electrical circuits. The generator output will back-feed into the utility power line. This may electrocute a power company line repair person. Also, if generator is powering electri- cal circuits, the chance of an elec- trical fire exists.

Note: We supply the engine owner’s manual with generator. Refer to that manual for questions concerning engine operation.

USING RECEPTACLE

Note: Do not exceed amperage rating of receptacles. Exceeding rating will trip re- ceptacle circuit breaker.

Use receptacles properly. Improper use could damage generator. Use only grounded exten- sion cords. Power only grounded or double- insulated items. Do not overload receptacles. All generators (except models HWI3000, MGH3000G, MGH3000, and MGH3000PR) have the following receptacles (see Figure 17):

120V, 15-amp GFCI duplex receptacle

120V, 30-amp twist-lock receptacle

120/240V, 20 or 30-amp twist-lock receptacle

120V, 15-amp duplex receptacle

Model MGH10000A also has a 120/240V, 50-amp receptacle (see Figure 17).

Model HWI3000 has only the 120V, 20- amp duplex receptacle.

Models MGH3000G, MGH3000 and MGH3000PR have only the 120V, 15-amp GFCI duplex receptacle.

120V, 15-Amp GFCI Duplex

 

120V, 15-Amp Duplex

 

 

 

120/240V, 20 or

 

 

 

30-Amp Twist-Lock

120

VOLTS

 

 

 

 

 

 

 

 

 

 

RESET

 

 

 

 

 

TEST

 

 

 

 

 

120

 

 

 

 

 

ONLY

 

 

 

 

 

 

 

120

 

 

 

 

 

240V

 

 

 

0

ENM

 

 

 

00

 

 

 

 

H

000

 

 

 

OU

RS

05

R

E

 

 

1

 

 

 

/10

 

SET

120V, 30-Amp

 

 

RE

Twist-Lock

 

 

 

SET

 

 

 

 

RESET

240

VO

 

 

 

 

LTS

RESET

 

RESET

 

 

 

 

RESET

120/240V, 50-Amp

(Model MGH10000A only)

Figure 17 - Receptacle Locations

POWER CORD AND PLUG REQUIREMENTS

120V, 30-amp twist-lock receptacle

NEMA L5-30P plug

Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock receptacle

NEMA L14-20P (20-amp) or L14-30P (30-amp) plug

Four-wire, 20-amp or 30-amp cord

120/240V, 50-amp receptacle

NEMA L14-50P

Four-wire, 50-amp cord

Figure 18 - Cord and Plug Configurations