Masterbuilt MDCL manual Soapy Water Test Warning and Procedures, Extension Legs Assembly, Storage

Models: MDCL

1 8
Download 8 pages 32.47 Kb
Page 7
Image 7
Wind Guard Tabs

Soapy Water Test Warning and Procedures

The Soapy Water Test must be performed each time the gas cylinder is connected to your appliance or each time the appliance is used.

The Soapy Water Test must be performed outdoors in a well-ventilated area.

When performing the Soapy Water Test, always keep cooker away from open flames, sparks, or lit cigarettes.

The Outdoor Gas Cooker is designed to operate with propane gas only. This product will not operate with natural gas.

Never use an open flame to test for gas leaks.

Always remove any cookware from cooker stand when performing the Soapy Water Test.

PROCEDURE:

 

 

1. Remove any cookware from your cooker stand.

 

 

2. Turn valves to OFF position, and turn the gas

 

 

cylinder valve to the OFF position.

 

 

3. Prepare your soapy water solution by combining (1)

Hose,

Burner

Manifold

one part dish washing liquid with (3) three parts

Regulator

and

water to test for the possibility of any gas leaks in

and

Valves

the hose or connections to regulator, regulator

Cylinder

 

connection to gas cylinder and valves. Apply soapy

 

Valve

 

water solution to the gas cylinder valve, regulator

 

 

 

and up the hose to where it is connected to the

 

 

burner manifold and around the burner valves.

Bubbles in Soapy

Parts List

1

Double Cooker Frame

2

Valve Assembly (pre-mounted)

2

Cast Burners with Air Shutters,

2

Heat Shields (pre-mounted)

 

Springs and Bolts (pre-mounted)

1

Wind Guard Assembly

1

Hose/Tee Assembly (pre-mounted)

2

On/Off Control Knobs

1

Hose, Regulator Assembly

4

Extension Legs with 4 Wing Bolts

 

(pre-mounted)

 

 

 

(Cylinder Not Included)

Outdoor LP Gas Cooker Assembly Instructions

Extension Legs Assembly

Extension Legs

and Storage

 

Assembly:

Wing Bolt

Insert extension legs into leg holder on

 

cooker frame. Secure with wing bolt.

 

Storage:

 

Snap 2 legs into each bracket as

 

shown.

 

Water Test

4. Turn gas cylinder ON only, If bubbles appear, stop,

and retighten the fitting. Repeat test.

Control Knobs and Wind Guard Assembly

Control Knobs:

Wind Guard

5. After test is complete, and there are no leaks, wait

a minimum of 5 minutes for gas fumes to diminish

before lighting cooker.

DURING ANY PORTION OF THE SOAPY WATER TEST, IF BUBBLES CONTINUE TO APPEAR, STOP, DO NOT USE APPLIANCE, CONTACT YOUR LOCAL PROPANE DEALER OR CONTACT MASTERBUILT AT 800-489-1581.

NOTE: USE A 20 LB. CYLINDER OR SMALLER WITH A PROTECTIVE COLLAR WITH THIS APPLIANCE.

Align flat side of the control knob inset with flat side of control knob shaft and push knob firmly into place.

Wind Guard Assembly:

Secure back two mounting tabs onto the cooker frame as shown.

Control Knobs

Form left and right side of wind guard around the cooker security ring and slip remaining tabs into place.

 

Before each use check all nuts and bolts to be sure that

 

9

they are tight and secure.

6

Page 7
Image 7
Masterbuilt MDCL manual Soapy Water Test Warning and Procedures, Extension Legs Assembly, Storage