Maxon Telecom 1100, 850 Dimensions, 1 - 2.3 - 12 E - m - 7/08, w w w . m a x o n c o r p . c o m

Models: 700 550 1800 300 850

1 17
Download 17 pages 52.51 Kb
Page 7
Image 7
Dimensions

Low temperature burners - INDITHERM®

Dimensions

INDITHERM® with standard discharge sleeve - all sizes

1 - 2.3 - 12 E - m - 7/08

1)Gas inlet

2)Pilot gas connection

3)Combustion air test connec- tion

4)Gas pressure test connec- tion

5)90° capacity control crank

6)Filter housing (optional)

7)Stainless steel discharge sleeve (standard)

8)Flame supervision port

9)Spark ignitor

6

3

2

4

9 8

1 5 7

Dimensions in mm unless stated otherwise

burner size

gas inlet [1]

A

B

C

ØD

E

F

G

H

I

J

K

L

M

N

Ø P

S

Weight (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

1”

365

225

200

160

111

442

93

390

431

224

289

353

184

214

13

5

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

1

1/4”

365

224

200

210

111

442

91

390

431

224

289

353

226

264

13

5

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

550

1

1/2”

514

255

200

260

138

541

100

435

462

308

367

400

286

318

13

8

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

2”

598

255

200

260

138

786

71

435

500

387

403

448

286

318

13

8

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

850

 

2”

598

255

200

260

138

777

71

465

498

387

403

448

286

318

13

8

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1100

 

2”

597

365

200

311

165

777

136

560

593

387

403

448

340

375

13

8

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

 

2”

597

365

200

311

165

777

136

560

593

387

403

448

340

375

13

8

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

3”

659

365

200

311

165

809

136

605

663

451

452

480

340

375

13

8

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1] gas inlet is threaded, available in ISO or NPT.

w w w . m a x o n c o r p . c o m

combustion systems for industry

MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved.

Page 7
Image 7
Maxon Telecom 1100, 850, 550, 700, 300, 1800, 1500 Dimensions, 1 - 2.3 - 12 E - m - 7/08, w w w . m a x o n c o r p . c o m