Maxon Telecom 850, 550, 700, 300, 1800 1 - 2.3 - 13 E - m - 7/08, w w w . m a x o n c o r p . c o m

Models: 700 550 1800 300 850

1 17
Download 17 pages 52.51 Kb
Page 8
Image 8
1 - 2.3 - 13 E - m - 7/08

Low temperature burners - INDITHERM®

INDITHERM® with high temperature discharge sleeve - all sizes

1 - 2.3 - 13 E - m - 7/08

1)Gas inlet

2)Pilot gas connection

3)Combustion air test connec- tion

4)Gas pressure test connec- tion

5)90° capacity control crank

6)Filter housing (optional)

7)High temperature discharge sleeve

8)Flame supervision port

9)Spark ignitor

6

 

 

 

4

 

 

 

9

1

 

7

8

5

 

 

 

 

3

2

Dimensions in mm unless stated otherwise

burner size

gas inlet [1]

A

B

C

ØD

E

F

G

H

I

J

K

L

ØM

ØN

Ø P

S

Weight (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

1”

365

232

200

257

111

442

100

397

438

224

289

353

320

357

14

12

47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

1

1/4”

365

231

200

305

111

442

98

397

438

224

289

353

368

405

14

12

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

550

1

1/2”

514

259

200

357

138

541

104

439

466

308

367

400

420

457

14

12

83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

2”

598

259

200

357

138

786

75

439

504

387

403

448

420

457

14

12

83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

850

 

2”

598

259

200

357

138

777

75

469

502

387

403

448

420

457

14

12

83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1100

 

2”

597

369

200

408

165

777

140

564

597

387

403

448

471

508

14

12

110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

 

2”

597

369

200

408

165

777

140

564

597

387

403

448

471

508

14

12

110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

3”

659

369

200

408

165

809

140

609

667

451

452

480

471

508

14

12

110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1] Gas inlet is threaded, available in ISO or NPT.

w w w . m a x o n c o r p . c o m

combustion systems for industry

MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved.

Page 8
Image 8
Maxon Telecom 850, 550 1 - 2.3 - 13 E - m - 7/08, w w w . m a x o n c o r p . c o m, Low temperature burners - INDITHERM