AT INTERFACE DESCRIPTION

Pin Description Table

PIN NAME

PIN

I/O

SIGNAL NAME

SIGNAL DESC RIPTION

 

 

 

 

 

RESET -

01

I

Hos t Reset

Reset signal from the host s ystem. Active during power up and inactive after.

 

 

 

 

 

D D0

17

I/O

Host Data Bus

16 bit bi-directional data bus between host and drive. Lower 8 bits used for

 

 

 

 

register and EC C byte transfers. All 16 bits us ed for data transfers.

 

 

 

 

 

D D1

15

I/O

 

 

 

 

 

 

 

D D2

13

I/O

 

 

 

 

 

 

 

D D3

11

I/O

 

 

 

 

 

 

 

D D4

09

I/O

 

 

 

 

 

 

 

D D5

07

I/O

 

 

 

 

 

 

 

D D6

05

I/O

 

 

 

 

 

 

 

D D7

03

I/O

 

 

 

 

 

 

 

D D8

04

I/O

 

 

 

 

 

 

 

D D9

06

I/O

 

 

 

 

 

 

 

DD 10

08

I/O

 

 

 

 

 

 

 

D D11

10

I/O

 

 

 

 

 

 

 

DD 12

12

I/O

 

 

 

 

 

 

 

DD 13

14

I/O

 

 

 

 

 

 

 

DD 14

16

I/O

 

 

 

 

 

 

 

DD 15

18

I/O

 

 

 

 

 

 

 

D MARQ

21

O

DM A Request

This signal is used with DM AC K for D MA transfers . By asserting this s ignal, the

 

 

 

 

drive indicates that data is ready to be transfered to and from the host.

DIOW -

23

I

Host I/O Write

Rising edge of Write strobe clock s data from the hos t data bus to a register on

STOP

 

 

 

the drive.

D IOR -

25

I

Host I/O Read

Read strobe enables data from a register on the drive onto the host data bus.

HD MARDY

 

 

 

DMA ready during UltraDMA data in bursts.

-

 

 

 

Data strobe during UltraDMA data out bursts.

HSTROBE

 

 

 

 

 

 

 

 

 

IORDY

27

O

I/O C hannel Ready

This signal may be driven low by the drive to insert wait states into host I/O

DD MARDY

 

 

 

cycles.

-

 

 

 

D MA ready during UltraDMA data out bursts.

DSTROBE

 

 

 

D ata strobe during UltraDMA data in bursts.

CSEL

28

 

C able Select

Us ed for Mas ter/Slave selection via cable. Requires s pecial cabling on host

 

 

 

 

s ystem and installation of C able Select jumper.

 

 

 

 

 

D MACK -

29

I

D MA Acknowledge

This signal is used with DM ARQ for D MA transfers . By asserting this s ignal, the

 

 

 

 

host is ac knowledging the receipt of data or is indicating that data is available.

 

 

 

 

 

INTRQ

31

O

Hos t Interrupt

Interrupt to the host asserted when the drive requires attention from the host.

 

 

 

Request

 

IOC S16

32

 

D evice 16 bit I/O

Obsolete

 

 

 

 

 

PD IAG -

34

I/O

Pas sed D iagnostic

Output by drive when in Slave mode; Input to drive when in Master mode.

 

 

 

 

 

DA0

35

I

Hos t Address Bus

3 bit binary address from the host to selec t a regis ter in the drive.

 

 

 

 

 

DA1

33

I

 

 

 

 

 

 

 

DA2

36

I

 

 

 

 

 

 

 

C S0 -

37

I

Host Chip Select 0

C hip selec t from the host used to access the C omm and Block registers in the

 

 

 

 

drive. This signal is a decode of I/O addres ses 1F0 - 1F 7 hex.

 

 

 

 

 

C S1 -

38

I

Host Chip Select 1

Chip select from the host used to access the Control registers in the drive. This

 

 

 

 

signal is a decode of I/O addres ses 3F6 - 3F 7 hex.

DASP -

39

I/O

Drive Active/D rive

Time-multiplexed, open collector output which indicates that a drive is active, or

 

 

 

1 Present

that

 

 

 

 

device 1 is pres ent.

 

 

 

 

 

GND

02

N/A

Ground

Signal ground.

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

KEY

20

N/A

Key

Pin used for keying the interface connector.

 

 

 

 

 

5 – 2

Page 27
Image 27