Maytag BRAVOSTM manual Drain System, Electrical Requirements, Laundry tub drain system view C

Models: BRAVOSTM

1 84
Download 84 pages 63.81 Kb
Page 6
Image 6

For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

 

 

3"*

14"* max.

48 in.2 *

(7.6 cm)

(35.6 cm)

 

17"*

(310 cm2)

 

 

 

(43.2 cm)

 

 

 

2

 

 

24 in.2*

3"*

 

(155 cm )

(7.6 cm)

 

 

1"

 

 

 

 

27¹⁄₂"

 

 

 

1"

 

 

1"*

 

 

27"

 

 

5"*

 

 

 

(2.5 cm)

 

(69.9 cm)

 

(2.5 cm)(2.5 cm) (68.6 cm) (12.7 cm)

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

B

 

 

 

C

A. Front view

B. Side view

C. Closet door with vents

*Required spacing

Drain System

The washer can be installed using the standpipe drain system (floor or wall), the laundry tub drain system, or the floor drain system. Select the drain hose installation method you need. See “Tools and Parts.”

Standpipe drain system—wall or floor (views A & B)

The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter standpipe adapter kit is available. See “Tools and Parts.”

The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (244 cm) from the bottom of the washer.

39"

(99 cm)

AB

Laundry tub drain system (view C)

The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 39" (99 cm) above the floor and no higher than 96" (244 cm) from the bottom of the washer.

Floor drain system (view D)

The floor drain system requires a siphon break that may be purchased separately. See “Tools and Parts.”

The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses might be needed.

39"

28"

(71 cm)

(99 cm)

CD

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time- delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided.

6

Page 6
Image 6
Maytag BRAVOSTM manual Drain System, Electrical Requirements, Standpipe drain system-wall or floor views a & B