Maytag DC68-02033B-03 installation instructions Export Models

Models: DC68-02033B-03

1 13
Download 13 pages 3.49 Kb
Page 10
Image 10

3-WIRE SYSTEM CONNECTIONS

1.Loosen or remove center terminal block screw.

2.Connect neutral wire (white or center wire) of power supply cord to the center, silver colored terminal screw of the terminal block. Tighten screw.

3.Connect the other wires to outer terminal block screws. Tighten screws.

4.Tighten strain relief screws.

5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw.

1.External ground connector

2.Neutral grounding wire (green/yellow)

3. Center silver-colored terminal block screw

4. Neutral wire (white or center wire)

5. 3/4 in. (1.9 cm) UL-listed strain relief

WARNING: If converting from a 4-wire electrical system to a 3-wire, the ground strap must be reconnected to the terminal block support to ground the dryer frame to the neutral conductor.

4-WIRE SYSTEM CONNECTIONS

1.Remove center terminal block screw.

2.Connect ground wire (green or bare) of power supply cord to external ground conductor screw.

3.Connect neutral wire (white or center wire) of power supply cord and appliance ground wire (green with yellow stripes) under central screw of the terminal block.

4.Connect the other wires to outer terminal block screws. Tighten screws.

5.Tighten strain relief screws.

6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

1. External ground connector

2. Green or bare copper wire of power supply cord

3. 3/4 in. (1.9 cm) UL-listed strain relief 4.Center silver-colored terminal block screw 5 Grounding wire (green/yellow)

6. Neutral wire (white or center wire)

EXPORT MODELS

Refer to last page of installation instructions.

10

Page 10
Image 10
Maytag DC68-02033B-03 installation instructions Export Models