Maytag HE21250PC, HE21282PC operating instructions Wiring, Instructions for Installation contd

Models: HE21282PC HE21250PC

1 40
Download 40 pages 60.12 Kb
Page 16
Image 16
Wiring

Instructions for Installation (cont'd)

Wiring

•i_ CAUTION

Never use this water heater unless it is completely full of water. To prevent damage to the tank and

heating element, the tank must be filled with water. Water must flow from the hot water faucet

before turning on power.

You must provide all wiring of the proper size outside of the water heater. You must obey local codes and electric company requirements when you install this wiring.

Ifyun are not familiar with electric codes and practices, or if you have any doubt, even the slightest doubt, in your ability to connect the wiring to this water heater, obtain the service of a

competent electrician. Call Maytag Customer Service at 1-800-788-8899 for an authorized servicer,

WARNING

WATER HEATERS EQUIPPED FOR ONE VOLTAGE

ONLY: This water heater is equipped for one type voltage only. Check the rating plate near the bot- tom access panel for the correct voltage. DO NOT use this water heater with any voltage other than

the one shown on the model rating plate. Failure to use the correct voltage can cause problems which

can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or

doubts consult your electric company,

ACAUTION

If wiring from your fuse box or circuit breaker box was aluminum for your old water heater, replace it

with copper wire. If you wish to reuse the existing aluminum wire, have the connection at the water

Mayta_ Customer Service at 1-800-788-8899 for an authorized servicer.

1. Provide a way to easily shut off the electric power when

breaker or fuse block in the entrance box or a separate dis- connect switch.

2. Install and connect a circuit directly from the main fuse or

circuit breaker box. This circuit must be the right size and workinghave its ownon thefuswatero cibeatercuit. brTeakehis r.couldReferbetowithhe chacircuitin

the "Product Specifications" section for the correct size wire and fuse or circuit breaker.

3. If metal conduit is used for the grounding conductor:

A. The grounding electrode conductor shall be of copper, aluminum, or copperclad aluminum. The material shall be of one continuous length without a splice or joint.

B. Rigid metal conduit, intermediate metal conduit, or

electrical metallic tubing may be used for the grounding

means if conduit or tubing is terminated in fittings

 

approved for grounding.

16

C. Flexible metal conduit or 3 metallic tubing shall be per-

mitted for grounding if all the following conditions are met:

1.The length in any ground return path does not exceed 6 feet.

2.The circuit conductors contained therein are protected by overcurrent devices rated at 20 amperes or less.

3.The conduit or tubing is terminated in fittings

approved for grounding.

For complete grounding details and all allowable exceptions, refer to the latest edition of the National Electrical Code.

A s andar 1/,, -

4.t d ,_ conauit opening has been made in the water heater junction box for the conduit connection.

5.A wiring diagram (See "Wiring Diagram" Section) has been suppfied showing the connections between the water heater and the power supply. You can easily see the connection by removing the junction box cover on top of the water heater.

Connect red to red, black to black, and the ground wire to the green ground screw in the junction box of the water

heater.

6.Use wire nuts and connect the power supplywiring to the wires inside the water heater's junction box.

7.The water heater must be electrically "grounded" by the

installer. A green ground screw has been provided on the water heater's junction box. Connect ground wire to this

location.

8.Replace the wiring junction cover using the screw provided,

WIRE

T

CONDUIT _ /

/_

,@GsGR_

--

_

Page 16