Maytag MDB7650AWQ, MDB7600AWB Component Specifications, Illustration, Test Procedure, Results

Models: MDB6600AWB MDB7600AWS MDB7600AWQ MDB6600AWQ MDB7600AWW MDB7650AWW MDB6600AWW MDB6600AWS MDB7650AWQ MDB7650AWS MDB7650AWB MDB7600AWB

1 8
Download 8 pages 58.75 Kb
Page 3
Image 3
Results

Component Specifications

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power.

Illustration

Component

Test Procedure

 

Results

 

Limit Thermostat

Close on Temperature drop @ 149°F

 

 

 

 

± 7°F (Temp)

0

= Closed

 

 

Open on Temperature drop @ 164°F

 

 

 

 

± 4°F (Temp)

Infinite = Open

Sensor/Thermistor

10K± 3% at 77°F and 2.4 k ±

 

 

 

6.5% at 140°F

 

 

 

J5 pin 1 - Orange (Temp) to J5 Pin 4 -

Infinite = Open

 

Red (Neutral)

 

 

0

= Closed

 

 

 

 

Heater/Heating

Measure resistance from ST1

 

 

Element

Red/Black (Heater) to ST11 White

 

 

120v/60hz, 650 watts

(Common)

16

 

 

(This value assumes the high limit

± 5% in air, 830 watts

 

thermostat is closed).

± 5% in coldwater

 

 

 

 

 

 

 

Drain Motor

Measure resistance from

 

 

 

ST6 Gray (Drain) to ST4 Black

 

 

120v/60hz

(Common)

25

 

 

See section “Motor Connections and

 

 

 

Diagram” for wiring contacts.

 

 

May 2004

3

16023212

©2004 Maytag Services

 

 