![B. INVERT CAP IN APPLIANCE PRESSURE REGULATOR (See figure 11)](/images/new-backgrounds/62945/6294517x1.webp)
B. INVERT CAP IN APPLIANCE PRESSURE REGULATOR (See figure 11)
With the appliance installed, the appliance regulator should be located as shown in figure 3, 4 or 5.
CONVERSION OF APPLIANCE
PRESSURE REGULATOR
FIGURE 11
C. LOW FLAME ADJUSTMENT (See figure 12)
This appliance is shipped from the factory with low and high flame settings adjusted for use with natural gas. To set for use with LP proceed as follows:
1. Remove control knob from valve stem.
CAUTION: NEVER USE A METAL BLADE TO PRY KNOB OFF. IF KNOB CANNOT BE EASILY REMOVED, TUCK THE FOLDS OF A CLOTH DISHTOWEL UNDER THE KNOB AND PULL THE TOWEL UPWARD WITH STEADY, EVEN PRES- SURE.
2.Carefully remove rubber grommet.
3.Locate the valve adjustment screw. See figure 12.
4.Insert a slender,
5.Turn the adjusting screw clockwise until tight
6.Replace rubber grommet and control knob.
7.Repeat for remaining burners.
KNOB
ADJUSTMENT
SCREW
KNOB HOLE
(KNOB AND GROMMET REMOVED)
FIGURE 12
After adjusting the screw the burner should produce a stable, steady blue flame of minimum size. The setting should be checked by turning knob from high to low several times without extinguishing the flame.
This operation will automatically provide the proper flame size at medium setting.
After Conversion Steps A, B and C have been completed, check the appearance of each burner flame at the Hi and Lo settings against figure 13. If the flames appear too large or too small, review each step to make sure it was completed correctly.
FLAME APPEARANCE AT HI AND LO
FIGURE 13
9