16008333
© 1996 Maytag Corporation
Analog Temperature Board Tests
To test the temperature board for proper function, use the
diagnostics chart below in conjunction with the 11 termi-
nal pin connector and an ohm meter.
TEMPERATURE CONTROL BOARD
5 11
GRAY
10
PINK
9
WHITE/YELLOW, D/ST RIP
E
8
GRAY
7
RED
6
WHITE/RED, D/STRIPE
4
PINK
3
VIOLET
2
CLOSED UP
TEMPERATURE CONTROL
BOARD
4
WHITE
Analog Temperature Control Board Diagnostics
Chart
PIN SOURCE OUTPUT/INPUT WIRE COLOR MEASURE
TO PIN #
VOLTS
OHMS
CONDITIONS
1 Neutral Input WHITE Line 120VAC
2 Not Used
3 Cold
Valve Output VIOLET 1 120VAC
4 Hot Valve Output PINK 1 120VAC
6 Timer (12
T Contact) Input WHITE/RED,
D/STRIPE 1 120VAC Wash Cycle on Timer
7 TC
Disable Input RED 6
OVDC
3-
24VDC
TC Option Deselected
TC Option Selected
8 Thermistor Input GRAY 11
10K-
100K
OHMS
Room Temperature
9
Temp
Selector
Switch
Cold
Wash
Input W HITE/YELLOW,
D/STRIPE 6 * ** OVDC Warm or Cold Wash
Selected
10
Temp
Selector
Switch Hot
Wash
Input PINK 6 * ** OVDC Hot or Warm Wash
Selected
11 Thermistor Input GRAY 8
10K-
100K
OHMS
Room Temperature
* Reference DC voltages to line 1.
** Temperature only occurs during cold or warm wash
fills.
16023083
SECTION 9. TROUBLESHOOTING 9-11