Complete Installation

Electronic Ignition System

Initial lighting and gas flame adjustments

This cooktop is equipped for electronic auto-reignition by means of a spark igniter located at the rear of each burner. The burners are designed to light at any valve rotation that admits sufficient gas flow to support a flame and to automatically relight following a loss of flame due to a draft or other adverse condition. This feature is provided only as a convenience.

Check Flame Height

Adjust the height of surface burner flames.

The surface burner “low” flame should be a steady blue flame approximately ¼" (0.64 cm) high.

A

Check Operation of Surface Burners

Push in and turn the surface burners control knobs to light.

The surface burner flame should light within 4 seconds. The first time a surface burner is lighted it may take longer that 4 seconds to light because of air in the gas line.

Check the flame on “HIGH” for a blue color. It should be clean and soft in character. No yellow tip, blowing or lifting of flame should occur. Occasional orange flashes are normal and reflect different elements in the air or gas.

After verifying the proper burner operation, turn the control knobs to “OFF.”

If burners do not light properly:

Turn surface burner control knob to the “OFF” position.

Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown.

Check that the gas shutoff valves are set to the “open” position.

Check that burner caps are properly positioned on burner bases.

Recheck operation of surface burners. If a burner does not light at this point, contact your dealer or authorized service company for assistance.

B

A.Low flame

B.High flame

If the “low” flame needs to be adjusted:

This cooktop is shipped from the factory with low and high flame settings adjusted for use with Natural gas.

To set for use with LP, the flame can be adjusted using the adjustment screw located underneath the control knob.

A

B

C

A. Adjustment screw

B. Knob hole (knob removed)

C. Control knob

1.Remove the control knob from valve stem.

2.Remove rubber grommet.

3.Use a small flat-blade screwdriver to turn the adjustment screw clockwise until tight. Do not overtighten.

4.Replace rubber grommet and control knob.

5.Repeat for remaining burners.