INSTALLATION INSTRUCTIONS
Prepare Cooktop for Installation
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop. Failure to do so can result in back or other injury.
1.Decide on the final location for the cooktop.
2.Using 2 or more people, place the cooktop upside down on a covered surface.
3.Remove foam strip from literature packing. Remove backing from foam strip. Apply foam strip
NOTE: The foam strip keeps debris from the underside of the cooktop glass and helps the cooktop sit flat on uneven counters.
A
B
C
A. Cooktop base
B. Foam strip
C. Cooktop
2.Remove junction box cover, if present.
3.Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector.
4.Tighten screws on conduit connector if present.
5.See “Electrical Connection Options” chart to complete installation for your type of electrical connection.
Electrical Connection Options
If your home has: | And you will be | Go to Section: |
| connecting to: |
|
A fused | ||
| disconnect or | Home Power |
| circuit breaker | Supply |
5" | box |
|
|
| |
(12.7 cm) |
|
|
A fused | ||
| disconnect or | Home Power |
| circuit breaker | Supply |
3¹⁄₂" | box |
|
|
| |
(8.9 cm) |
|
|
4-Wire Cable from Home Power Supply
IMPORTANT: Use the
A
Install Cooktop
B
E
1. | Using 2 or more people, turn cooktop right side up. |
2. | Place cooktop in cutout. |
| NOTE: Make sure that the front edge of the cooktop is parallel |
| to the front edge of the countertop. If repositioning is needed, |
| lift entire cooktop up from cutout to avoid scratching the |
| countertop. |
|
|
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, fire, or electrical shock.
This cooktop is manufactured with the frame connected to the bare ground wire. Connect the cooktop cable to the junction box through the UL listed or CSA approved conduit connector.
1.Disconnect power.
F
G
C | H |
| |
D | I |
| |
A. Cable from home power supply | F. White wire (from home power |
B. Red wires | supply) |
C. Green or bare ground wires | G. UL listed wire connector |
D. | H. Black wires |
E. Junction box | I. UL listed or CSA approved |
| conduit connector |
1.Connect the 2 black wires together using the UL listed wire connectors.
2.Connect the 2 red wires together using the UL listed wire connectors.
3.Connect the green (or bare) ground wire from the cooktop cable to the green (or bare) ground wire (in the junction box) using the UL listed wire connectors.
4.Put a UL listed wire connector on the end of the white wire.
NOTE: Do not connect the bare ground wire to the neutral (white) wire in the junction box.
5.Install junction box cover.
6.Reconnect power.
4