Electrical Connection - U.S.A. Only

Power Supply Cord

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

Direct Wire

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

1.Disconnect power.

2.Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range. Pull cover down and toward you to remove cover.

4.Add strain relief.

Style 1: Power supply cord strain relief

Assemble a UL listed strain relief in the opening.

A

3. Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.

A. UL listed strain relief

Feed the power supply cord through the strain relief in the

cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

Tighten strain relief screw against the power supply cord.