Maytag W10296136A-SP Plan Vent System, Recommended exhaust installations, Elbows, Clamps, Exhaust

Models: MGDC500VW

1 28
Download 28 pages 47.83 Kb
Page 9
Image 9
Plan Vent System

■■ Must be fully extended and supported when the dryer is in its

 

final location.

 

 

■■

Remove excess flexible metal vent to avoid sagging

 

and kinking that may result in reduced airflow

and

poor

 

performance.

 

 

■■

Do not install flexible metal vent in enclosed

walls,

ceilings,

 

or floors.

 

 

Plan Vent System

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

■■ The total length of flexible metal duct shall not exceed

7¾ ft. (2.4 m).

Elbows:

■■ 45° elbows provide better airflow than 90° elbows.

GoodBetter

Clamps:

■■ Use clamps to seal all joints.

■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct

A

A.Dryer

B.Elbow

C.Wall

D.Exhaust hood

E.Clamps

B

Recommended exhaust installations C

Elbows:D

E

F

G

 

B

I

H

F. Rigid metal or flexible

metal vent

G.Vent length necessary to connect elbows

H.Exhaust outlet

I.Optional side exhaust outlet (27" wide models only)

and catch lint. Do not use duct tape.

Clamp

 

Exhaust:

 

Recommended hood styles.

Acceptable hood style.

B

C

 

4"

A

(102 mm)

 

4"

2½"

(102 mm)

(64 mm)

4"

 

(102 mm)

 

A.Louvered hood style

B.Box hood style

C.Angled hood style is acceptable

■■ An exhaust hood should cap the vent to keep rodents and insects from entering the home.

■■ Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

■■ Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

GoodBetter Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Clamps: Housecleaning problems and health problems.

Optional exhaust installations:

27" Wide Models can be converted to exhaust out the right side, left side, or through the bottom. Each kit includes step-by- step instructions. For further information, please reference the “Assistance or Service” section of the “Dryer User Instructions.”

9