3-wire Power Supply Cord Connection
Use where local codes permit connecting
3. Connect remaining wires
type | Connect remaining wires to outer terminal block screws. |
| Tighten screws. Finally, reinsert tab of terminal block cover |
| into slot of dryer rear panel. Secure cover with |
| screw. Now, go to “Venting Requirements.” |
| DIRECT WIRE CONNECTION |
Spade terminals with | Ring terminals |
upturned ends |
|
1. Remove center screw
B |
Remove center terminal block screw (B).
2. Connect neutral wire
B |
C |
Connect neutral wire (white or center) (C) of power supply cord to center terminal block screw (B). Tighten screw.
Direct Wire Strain Relief
1. Attach direct wire strain relief
A |
B |
C |
Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief
(C)through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads.