COMPLETE INSTALLATION CHECKLIST

qCheck that all parts are now installed. If there is an extra part, go back through steps to see what was skipped.

qCheck that you have all of your tools.

qDispose of/recycle all packaging materials.

qCheck dryer’s final location. Be sure vent is not crushed or kinked.

qCheck that dryer is level. See “Level Dryer.”

qRemove film on console and any tape remaining on dryer.

qWipe dryer drum interior thoroughly with a damp cloth to remove any dust.

qRead “Dryer Use” in your “Use and Care Guide.”

qFor power supply cord installation, plug into a grounded outlet. For direct wire installation, turn on Power.

Steam models only:

qBe sure the water faucets are on.

qCheck for leaks around “Y” connector, faucet, and hoses.

qIf you live in a hard water area, use of a water softener is recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair.

All Models:

qSelect a Time Dry heated cycle, and start dryer. Do not select Air Only Temperature setting.

If dryer will not start, check the following:

Controls are set in a running or “On” position.

Start button has been pushed firmly.

Dryer is plugged into an outlet and/or electrical supply.

Household fuse is intact and tight, or circuit breaker has not tripped.

Dryer door is closed.

This dryer automatically runs an installation diagnostic routine at the start of its first cycle.

If you receive an L2 code, there may be a problem with you home power supply keeping the dryer’s heater from turning on. See “Troubleshooting.”

If your Airflow screen reads “Check Vent”, your dryer vent may be crushed or blocked. See “Troubleshooting.”

NOTE: You may notice an odor when dryer is first heated. This odor is common when heating element is first used. The odor will go away.

REVERSE DOOR SWING

You can change your door swing from a right-side opening to a left-side opening, if desired.

1.Place a towel or soft cloth on top of dryer or work space to avoid damaging the surface.

Remove the door assembly

1.Open the dryer door.

2.Remove the bottom screw (B) from each of the two hinges that attach dryer door to front panel of dryer.

3.Loosen the top screw (A) from each of the two hinges in Step 2.

A

B

A

B

A. Top screw

B. Bottom screw

4.Remove the dryer door and the hinges by lifting upward on the door. Lay the door on a flat, covered surface, with the inside of the door facing up. Remove remaining two loose screws from dryer front panel.

5.Remove the 4 plastic plugs located outside the dryer door opening.

6.Install 4 plastic plugs into screw holes in the dryer left where the hinges were removed in Step 4.

18

Page 18
Image 18
Maytag W10562339B-SP Complete Installation Checklist, Reverse Door Swing, Remove the door assembly, Steam models only