Maytag W10562339B-SP Connect neutral ground wire and neutral wire, Connect ground wire

Models: W10562335B W10562339B-SP

1 20
Download 20 pages 35.46 Kb
Page 8
Image 8

If your outlet looks like this:

Power supply cord 4-wire receptacle (NEMA Type 14-30R):

Go to “4-Wire Power Supply Cord Connection” on this page.

Power supply cord 3-wire receptacle (NEMA Type 10-30R):

Go to “3-Wire Power Supply Cord Connection” on page 9.

4-wire Power Supply Cord Connection

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

2. Connect neutral ground wire and neutral wire

E

B

C

Connect neutral ground wire (E) and neutral wire (white) (C) of power supply cord under center terminal block screw (B). Tighten screw.

3. Connect ground wire

4-wire receptacle (NEMA type 14-30R)

Spade terminals with upturned ends

4-prong plug

Ring terminals

A

F

Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.

1. Prepare to connect neutral ground wire and neutral wire

E

A

B

Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).

4. Connect remaining wires

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.”

8

Page 8
Image 8
Maytag W10562339B-SP Connect neutral ground wire and neutral wire, Connect ground wire, Connect remaining wires