| Installation | |
Installation |
|
|
|
| |
The MCD201 can be placed upright on a table or shelf, | 2 inches (5.08cm) above the top, 2 inches (5.08cm) below | ||||
standing on its four feet. It also can be custom installed in | the bottom and 1 inch (2.54cm) on each side of the Audio | ||||
a piece of furniture or cabinet of your choice. The four feet | Control Center, so that airflow is not obstructed. Allow 17 | ||||
may be removed from the bottom of the MCD201 when it | inches (43.18cm) depth behind the front panel. Allow | ||||
is custom installed as outlined below. The four feet togeth- | inch (2.9cm) in front of the mounting panel for knob clear- | ||||
er with the mounting screws should be retained for possible | ance. Be sure to cut out a ventilation hole in the mounting | ||||
future use if the MCD201 is removed from the custom | shelf according to the dimensions in the drawing. | ||||
installation and used free standing. The required panel |
|
| |||
cutout, ventilation cutout and unit dimensions are shown. |
|
| |||
Always provide adequate ventilation for your MCD201. |
|
| |||
Cool operation |
|
|
| ||
ensures the |
|
|
| ||
|
| 43.34cm |
| ||
longest pos- |
|
|
| ||
|
|
|
| ||
sible operat- |
|
|
|
| |
ing life for | MCD201 Front Panel |
|
|
| |
any electronic |
|
| |||
instrument. | Custom Cabinet Cutout |
|
| 12.38cm | |
Do not install |
|
|
|
| |
the MCD201 |
|
|
|
| |
directly above |
|
|
|
| |
a heat generat- |
|
|
|
| |
ing compo- |
|
|
|
| |
nent such as a |
|
| Cutout Opening for Custom Mounting | ||
high powered |
|
| |||
|
|
|
| ||
amplifier. If |
| Cabinet |
|
| |
all the com- |
| Front |
|
| |
ponents are |
| Panel |
|
| |
installed in a |
|
|
|
| |
single cabinet, |
|
|
|
| |
a quiet running | MCD201 Side View |
|
|
| |
ventilation |
|
|
| ||
in Custom Cabinet |
|
|
| ||
fan can be a |
|
|
| ||
|
|
|
| ||
definite asset |
|
| Cutout Opening for Ventilation |
| |
in maintaining |
| Support |
| Chassis | |
all the system |
|
| |||
| Spacers | ||||
components at |
| Shelf |
| ||
|
| 2.70cm |
| ||
the coolest pos- |
|
|
|
| |
sible operating |
|
|
|
| |
temperature. |
| 1" |
| ||
A custom cabi- |
|
| |||
| 21.91cm |
| |||
| 2.54cm |
| |||
net installation | MCD201 Bottom View | ||||
| |||||
should provide | in Custom Cabinet |
| 39.37cm | 38.26cm | |
the follow- |
|
| Cutout Opening |
| |
ing minimum |
|
|
| ||
|
| for Ventilation |
| ||
spacing dimen- |
|
|
|
| |
sions for cool |
| 3" |
|
| |
operation. |
|
|
| ||
| 7.62cm |
| |||
Allow at least |
|
| |||
Note: Center the cutout Horizontally on the unit. |
| ||||
| 31.27cm |
| |||
| For purposes of clarity, the above |
|
| ||
| � |
|
|
| |
| illustration is not drawn to scale. |
|
|
| |
8 |
|
|
|
|