Meade LX90GPS Identify, Alternate Alt/Az Alignments, To perform a Landmark Survey, Example

Models: LX90GPS

1 60
Download 60 pages 31.07 Kb
Page 38
Image 38

2.Display the "Landmark: Select" menu option. Press ENTER.

3.Use the Scroll keys to scroll through the list of objects you have previously entered. When the desired object displays, press ENTER to select the object. Use the Scroll keys to scroll through location information about the object, if desired. Press GO TO to slew the telescope to the landmark.

4.Press MODE to exit.

To perform a Landmark Survey

This procedure allows you to perform a tour of the objects entered in the "Object: Landmark" menu option – note that the Landmark Survey will function only if you have previously entered objects in the Landmark menu.

1.Navigate to "Utilities: Landmark Survey" menu and press ENTER.

2."Landmark Survey: Slewing..." displays. The telescope moves to the first object on the Survey list and displays the name of the object.

3.Press MODE to pause the Survey. Press ENTER to restart the survey at the first object of the survey.

To check on the available amount of memory in AutoStar.

AutoStar has a limited amount of memory. Once you begin to store Landmarks, User Objects and other bits of information in AutoStar, you will begin to use up memory. This procedure allows you to check on how much memory is still available.

1.Navigate to the "Setup: Statistics" menu option and press ENTER.

2."Statistics: 37.2K Char. Free" displays. This is the amount of memory that is still available to the user.

Identify

This procedure allows you to use AutoStar to identify objects you have found in the night sky using the Arrow keys. If the object is not in AutoStar's database, AutoStar displays information about an object in its database that is closest to the one you queried about.

IMPORTANT NOTE: Set the home position if you are using One-Star, Two-Star or Easy Alignment—see page 38. If you physically move the telescope after align- ment, this function will fail to operate properly.

In this procedure, you will center an object you wish to have identified by AutoStar in the telescope eyepiece and use the "Identify" menu to find out information about the object or the nearest object to it in the AutoStar database.

1.Center the object you wish to have identified in the telescope's eyepiece.

2.Navigate to the "Object: Identify" option and press ENTER.

3."Searching..." displays. When AutoStar finishes calculating, the name of the closest object displays.

4.Press a Scroll key to display information about this object. AutoStar displays some or all the following information about the object with each press of a Scroll key:

Displayed information:

Example:

Catalog or common name of object

Messier 107, NGC6171, Orion Nebula, etc

Type of object

Globular Cluster, Nebula, Black Hole, etc.

Right Ascension

16:32:4

Declination

13°03'

Constellation

Virgo, Orion, etc.

Magnitude

3

Size

2'

Scrolling message

"This Globular Cluster is 10,000 light years

 

away...."

Alternate Alt/Az Alignments

If you would rather set up your telescope without using automatic alignment, AutoStar offers alternative alignment methods for both alt/az and equatorial mounting. During the One-Star and