In order for the SmartFinder to be useful, it must first be aligned with the main telescope, so that both the SmartFinder and the main telescope are pointing at precisely the same location. To align the SmartFinder:

1.Point the main telescope at some well-defined distant (perhaps a mile away) land object, such as a telephone pole or sign. Center the object, as precisely as possible, in the SP 26mm eyepiece's field of view. Tighten the vertical and horizontal locks (6 and 9, Fig. 1) so that the tube cannot move and the object remains centered.

2.While looking through the SmartFinder (1, Fig. 6), turn the top or side alignment screws (2 and 3, Fig. 7), until the red dot of the SmartFinder points at precisely the same position as the view through the eyepiece of the main telescope.

The SmartFinder is now aligned to the main telescope. Unless the alignment screws are disturbed or the LNT Module is moved out of place, the SmartFinder should remain aligned indefinitely.

AAligning the Viewfinder

Manual backgroundB C

Fig. 6a: SmartFinder Location.

Fig. 6b: Turn the top (2) or side

(3) SmartFinder.

Aligning the Viewfinder

Like the SmartFinder, the viewfinder helps you locate objects and must also be aligned to the main telescope. To align the viewfinder, perform steps 1 through 5 during the daytime; perform step 6 at night.

1.Slide the track on the bottom of the viewfinder into the slot in the viewfinder mounting assembly. See Fig. 7a. To secure the viewfinder to the mounting assembly, tighten the two thumbscrews (Fig. 7a) to a firm feel only.

2.If you have not already done so, insert the Super Plössl 26mm eyepiece into the diagonal prism.

3.Unlock the R.A. (9, Fig. 1) and Dec (7, Fig. 1) locks so that the telescope moves freely on both axes.

4.Point the telescope at some well-defined and stationary land object at least 200 yards dis- tant, such as the top of a telephone pole or street sign. Center the object in the telescope eyepiece. Re-tighten the R.A. and Dec locks.

5.Look through the viewfinder eyepiece (Fig. 7b) and loosen or tighten, as appropriate, one or more of the viewfinder alignment screws (Fig. 7b) until the viewfinder crosshairs are pre- cisely centered on the object you previously centered in the telescope eyepiece.

6.Check this alignment on a celestial object, such as the Moon or a bright star, and make any necessary refinements, using the method outlined in steps 3 and 4.

Mounting