Troubleshooting
16

Troubleshooting

No front panel indicator is shown

Check that your AC power supply is connected
correctly.
Check that the ON OFF switch on the back panel is in the ON
position.
Check that the unit has been taken out of standby using the
front panel button or TRIGGER INPUT.
Check that the fuse on the multi channel power amplifier back
panel and the fuse in the unit’s power plug have not blown;
see To change the mains fuse, page 17.

The sound has cut out

The 558 Multi Channel Power Amplifier includes a thermal
shutdown, which mutes the output if the amplifier becomes too
hot. The Standby LED will also become red.
Leave the amplifier for a few minutes to cool down, the
Standby LED will turn green and the sound will come back on.
The 558 Multi Channel Power Amplifier also includes a power
circuit breaker to protect the loudspeakers. This is also triggered
if the mains supply is interrupted.
Check the system for the cause of the cut out.
Switch off, wait 5 seconds, then switch on to reset the power.