13
INSTALLATION
INTERFACE
RS232
The following steps describe how to properly install the cables for an RS232 StratosE application. The scanner must
then be configured to match the host’s RS232 parameters. Cable installation alone does not guarantee that the StratosE
will communicate properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide (MLPN 00-02407x) and the MS2xxx
Stratos Series Configuration Addendum (MLPN 00-02034x).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the RS232 interface cable (MLPN 57-57200x-N-3) into the 10-pin socket labeled
Scanner RS232 to Host, on the bottom of the StratosE. Refer to figure shown below.
3. Connect the other end of the RS232 interface cable to the proper communication port on the host device.
Before continuing, verify that the RS232 interface cable is connected to the appropriate interface socket on the
scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner
and/or terminal.
4. Plug the external power supply into the 3-pin Molex socket labeled, DC Power In on the bottom of the StratosE.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
should be located near the equipment and be easily accessible.
Metrologic recommends using a switched AC outlet. The switch should be located on the operator’s side of the
checkout counter in close proximity to the StratosE to facilitate service of the unit.
5. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
6. Turn on the host system.
7. Scan the Recall Defaults bar code.
8. Configure the StratosE to match the host system’s RS232 parameters.
Refer to the MetroSelect Configuration Guide (MLPN 00-02407x) under Section G: RS232, Enable RS232 Mode.
Figure 18. RS232 Interface Cable Installation Schematic
See power source caution statement on page 8 of this manual.