72 
SCANNER AND CABLE TERMINATIONS  
Aux Port Configuration Cable*, MLPN 57-57008x-N-3   
Pin  Function** 
1  No Connect 
2  Output from Scanner 
3  Input to Scanner 
4  No Connect 
5 Ground 
6-9  No Connect 
9-Pin D-Type Connector 
  RS232 LSO/AUX Cable, MLPN 57-57099x-3   
Pin  Function† 
1 Signal Ground 
2  RS232 from Aux / Secondary Scanner 
3  RS232 to Aux / Secondary Scanner 
4  RTS from Aux / Secondary Scanner 
5  CTS to Aux / Secondary Scanner 
6-8  No Connect 
9  + 5VDC – Transformer / Direct 
10 Shield Grou nd 
10-Position Modular Plug 
*   This configuration cable was designed to be used with the StratosS auxiliary connector only. 
** All signals are referenced from the StratosS scanner. 
†  All signals are referenced from the auxiliary / secondary scanner. 
Specifications are subject to change without notice.