5
RS232 AND LIGHT PEN SCANNER INSTALLATION
1. Turn off the host system.
2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the
bottom of the cradle. You will hear a ‘click’ when the connection is made.
3. Connect the plug of the power supply into the power jack on the bottom of
the cradle.
4. Connect the power supply into an AC outlet. The blue LED on the rear of the
cradle will stay on.
5. Connect the 9-pin D-type connector of the RS232 cable to the proper COM
port of the host system.
6. Turn on the host system.
Right installation does not guarantee that the scanned information will be
communicated properly to the host system. The scanner is shipped from
the factory programmed with default settings. Please refer to the
MetroSelect Programming Guide (MLPN 00-02544B) or MetroSet2’s help
files for instructions on changing the scanner’s configuration. In addition,
please check that the cradle and host system are using the same
communication protocol.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must
meet the requirements for SELV ( Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the
power source should meet applicable performance requirements for a limited power source.