JM-1P OPERATING INSTRUCTIONS
29
Wink LED (Green)
The green Wink LED lights when a signal is sent from the
RMS software by clicking the Wink button on the loud-
speaker’s icon or on its Text view. This is useful for identify-
ing the physical loudspeaker corresponding to a
loudspeaker icon in the RMS software.
Reset Button
Pressing the Reset button causes the RMS module’s firm-
ware to reboot; this will not affect whether the loudspeaker
is commissioned (which is stored in flash memory). You can
simultaneously press the Reset and Service buttons to reset
the RMS module and decommission the loudspeaker from
the network (see “Resetting the RMS Module” on page 29).
Activity LED (Green)
The green Activity LED flashes continuously when the loud-
speaker has been successfully commissioned.
Network Connectors
The two bi-directional Weidmuller locking connectors trans-
fer data to and from the RMS network. Two connectors are
provided to allow for easy connection of multiple (daisy-
chained) loudspeakers on the network.
RESETTING THE RMS MODULE
You can use the Reset and Service buttons to reset the RMS
module, which will cause the module to be decommissioned
from the network.
To reset the RMS module:
1. Press and hold the Service button for 10 seconds.
2. While continuing to hold down the Service button, press
and hold the Reset button for 5 seconds.
3. After releasing the Reset button, continue holding down
the Service button for 5 seconds. The RMS module is
reset and the loudspeaker is decommissioned. The RMS
module’s red Service LED blinks.