CWT Series

4D

NN

4E

00

53

00

53

02

55

00

57

00

5A

00

5A

01

5B

00

5B

01

5B

02

5B

03

5D

00

5D

01

5D

FF

5E

00

5E

01

5E

02

5E

03

5E

04

63

00

63

01

64

00

65

00

73

00

80

xx

MICROBOARDS TECHNOLOGY, LLC

TAGGED OVERLAPPED COMMANDS (NN=QUEUE TAG) OVAERLAPPED COMMANDS ATTEMPTED

MEDIA LOAD OR EJECTED FAILED

MEDIUM REMOVAL PREVENTED SYSTEM RESOURCE FAILURE

UNABLE TO RECOVER TABLE-OF-CONTENTS OPERATOR REQUEST OR STATE CHANGE INPUT OPERATOR MEDIUM REMOVAL REQUEST LOG EXCEPTION

THRESHOLD CONDITION MET

LOG COUNTER AT MAXIMUM

LOG LIST CODES EXHAUSTED

FAILURE PREDICTION THRESHOLD EXCEEDED - Predicted Logical Unit Failure FAILURE PREDICTION THRESHOLD EXCEEDED - Predicted Media Failure

FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE) LOW POWER CONDITION ON

IDLE CONDITION ACTIVATED BY TIMER STANDBY CONDITION ACTIVATED BY COMMAND IDLE CONDITION ACTIVATED BY COMMAND STANDBY CONDITION ACTIVATED BY COMMAND END OF USER AREA ENCOUNTERED ON THIS TRACK PACKET DOES NOT FIT IN AVAILABLE SPACE ILLEGAL MODE FOR THIS TRACK

VOLTAGE FAULT CD CONTROL ERROR VENDOR SPECIFIC

Write Errors

ASC

ASCQ

Description

00

00

NO ADDITIONAL SENSE INFORMATION

00

06

I/O PROCESS TERMINATED, PLAY OPERATION ABORTED

00

11

AUDIO PLAY OPERATION IN PROGRESS

00

12

AUDIO PLAY OPERATION PAUSED

00

13

AUDIO PLAY OPERATION SUCCESSFULLY

00

14

AUDIO PLAY OPERATION STOPPED DUE TO ERRPOR

00

15

NO CURRENT AUDIO STATUS TO RETURN

02

00

NO SEEK COMPLETE

04

00

LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE

04

01

LOGICAL UNIT IS IN PROCESS OF BECOMING READY

04

02

LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUIRED

04

03

LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED

04

04

LOGICAL UNIT NOT READY, FORMAT IN PROGRESS

04

07

LOGICAL UNIT NOT READY, OPERATION IN PROGRESS

04

08

LOGICAL UNIT NOT READY, LONG WRITE IN PROGRESS

05

00

LOGICAL UNIT DOES NOT RESPOND TO SELECTION

06

00

NO REFERENCE POSITION FOUND

08

00

LOGICAL UNIT COMMUNICATION FAILURE

08

01

LOGICAL UNIT COMUUNICATION TIME-OUT

08

02

LOGICAL UNIT COMMUNICATION PARITY ERROR

08

03

LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32)

09

00

TRACK FOLLOWING ERROR

09

01

TRACKING SERVO FAILURE

09

02

FOCUS SERVO FAILURE

09

03

SPINDLE SERVO FAILURE

0A

00

ERROR LOG OVERFLOW

0B

00

WARNING

0B

01

WARNING-SPECIFIED TEMPERATURE EXCEEDED

0B

02

WARNING-ENCLOSURE DEGRADED

0C

00

WRITE ERROR

0C

02

WRITE ERROR-RECOVERED WITH AUTO REALLOCATION

 

 

13

Page 13
Image 13
MicroBoards Technology CWT Series, CopyWriter Series user manual Write Errors