SECTION 2
INSTALLATION
NOTE: The oven, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code (NEC), or ANSI/NFPA70.
NOTE
There must be adequate clearance between the oven and any adjacent combustible con- struction. Clearance must also be provided for servicing and for operation.
CAUTION
It is recommended that the oven be placed under a ventilation hood for adequate air supply and ventilation.
CAUTION
Do not obstruct the flow of ventilation air to and from your oven. Do not obstruct the fan holes in the rear of the unit.
I. UNLOADING
Your Middleby Marshall
The crate and carton must be examined before signing the Bill of Lading. Report any visible damage to the transport company, and check for the proper number of crates. If apparent damage is found, make arrangements to file a claim against the carrier. Surface Interstate Commerce Regulations (U.S.A.) require that the claim must be initi- ated by the consignee within 10 days from the date that the shipment is received.
PARTS LIST FOR SERIES PS528 GAS OVEN
|
|
| INSTALLATION KIT |
|
|
| Single Stack Oven |
ITEM |
|
| P/N 63946 |
|
|
| |
NO. | QTY | PART NO. | DESCRIPTION |
1 | 4 | 3101908 | LEG 4″ AD FT |
2 | 1 | 62208 | INSULATION BOTTOM TRAY |
3 | 1 | 62206 | BOTTOM TRAY WELDMENT |
4 | 1 | 61650 | TOP COVER |
5 | 4 | 51387 | SCREW MSSLT THREAD |
7 | 1 | GAS HOSE RESTRAINT CABLE | |
8 | 1 | GAS HOSE | |
9 | 1 | 49975 | CORD & PLUG NEMA |
10 | 1 | MANUAL GAS VALVE, 3/4″ × 1/2, COUPLER | |
11 | 1 | 31823 | REDUCER, 3/4″ – 1/2″ |
12 | 4 | 62207 | INSULATION |
9
8
Figure 2-1. PS528-Series Gas Oven Installation Parts
7
10
11
8