Middleby Marshall PS740E Do Not Use Conduit For Ground Connection, Circuit Breaker, Supply Wire

Models: PS740E

1 36
Download 36 pages 39.71 Kb
Page 22
Image 22
UTILITY ROUGH-IN DIMENSIONS AND POSITIONING FOR PS740-SERIES OVENS

UTILITY ROUGH-IN DIMENSIONS AND POSITIONING FOR PS740-SERIES OVENS

WARNING

DO NOT USE CONDUIT FOR GROUND CONNECTION.

CAUTION

IT IS RECOMMENDED THAT THE OVEN BE PLACED UNDER A VENTILATION HOOD FOR ADEQUATE AIR SUPPLY AND VENTILATION.

ELECTRIC SUPPLY TO BE

PROVIDED BY CUSTOMER

To Oven DO NOT USE CONDUIT FOR GROUND CONNECTION.ELECTRIC SUPPLY TO BECIRCUIT BREAKER

To Oven ELECTRICAL SPECIFICATIONSFigure 2-19. Typical PS740-Series Oven(s)ELECTRICAL RATING

Suggested dimensions are shown; utility code requirements supersede any factors shown.

CIRCUIT BREAKER

Separate circuit breaker with lockout/tagout electrical shutoff for each oven. Wire each oven separately.

100 Amp circuit breaker for 208-240V, or 50 Amp circuit breaker for 380-480V.

ELECTRICAL SPECIFICATIONS

DOMESTIC: 208V main blower motors and elements,

3Ph, 75 Amp draw, 50/60 Hz, 208-240V control circuit,

3pole, 4 wire system per oven (3 hot, 1 grd).

Do NOT use conduit for ground.

or

DOMESTIC: 240V main blower motors and elements,

3Ph, 65 Amp draw, 50/60 Hz, 208-240V control circuit,

3pole, 4 wire system per oven (3 hot, 1 grd).

Do NOT use conduit for ground.

or

EXPORT: 380V elements, 3 Ph, 41 Amp draw, 50/60 Hz, 208-240V control circuit and main blower motor, 4 pole, 5 wire system per oven (3 hot, 1 neutral, 1 grd).

Do NOT use conduit for ground.

or

DOMESTIC: 480V elements, 3 Ph, 32.5 Amp draw, 50/60 Hz, 208-240V control circuit and main blower motor, 4 pole, 5 wire system per oven (3 hot, 1 neutral, 1 grd).

Do NOT use conduit for ground.

Figure 2-19. Typical PS740-Series Oven(s)

Installation

ELECTRICAL RATING

27.0 kW/hr.

SUPPLY WIRE

Supply wire size must be in accordance with the National Electrical Code (current edition) and must be in compliance with local codes.

NOTE: The electrical terminal connection marked “MP” located inside the control compartment is desiganated for the blue (neutral) wire to the oven. See the electrical wiring/schematics in Section 6 of this manual.

SUGGESTED

If space permits, service should be located near the control console end of the oven(s) to allow convenient access to safety switches.

18

Page 22
Image 22