MAXON

SP-300 HAND HELD

 

 

 

VOLTAGE CHARTS

 

 

 

 

 

 

 

 

 

 

CONTROL CIRCUIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX

 

 

TX

 

 

REF #

B

C

E

B

C

E

 

Q401

4.4

0.0

5.0

0.3

5.0

5.0

 

Q403

0.0

4.6

GND

0.0

4.6

GND

 

Q404

5.0

2.2

2.0

0.0

7.0

0.0

 

Q405

5.0

1.8

1.7

5.0

1.8

1.7

 

Q406

4.0

0.0

5.0

2.0

5.0

5.0

 

Q407

0.0

4.5

GND

5.0

0.0

GND

 

Q408

0.0

5.0

GND

2.0

0.0

GND

 

Q410

4.3

0.0

5.0

4.3

0.0

5.0

 

Q411

0.0

-

GND

0.0

0.0

GND

 

Q412

0.0

7.5

7.5

0.0

7.5

7.5

 

Q413

7.5

0.0

GND

7.5

0.0

GND

 

zNOTE: Q402 and Q409 are not fitted on this model series.

MAIN CIRCUIT

RXTX

REF #

B

C

E

B

C

E

Q1

0.6

5.0

5.0

0.6

5.0

5.0

Q2

5.0

0.0

5.0

0.3

4.7

5.0

Q3

0.0

4.7

5.0

5.0

0.0

5.0

Q4

0.0

5.0

5.0

0.0

5.0

5.0

Q5

4.7

0.0

5.0

4.7

0.0

5.0

Q6

4.0

18.0

5.0

4.0

18.0

5.0

Q7

18.0

~3.0

18.0

18.0

~4.0

18.0

Q8

5.0

0.0

5.0

5.0

0.0

5.0

Q11

0.0

3.0

0.0

0.0

4.0

0.0

Q12

1.6

4.5

1.0

0.0

0.0

0.0

Q13

4.6

4.6

4.0

0.0

0.0

0.0

Q14

0.0

0.0

0.0

4.6

4.6

4.0

Q16

0.0

0.0

0.0

1.4

4.8

0.8

Q17

0.0

0.0

0.0

0.6

3.0

GND

Q18

0.0

0.0

0.0

5.0

0.2

GND

Q21

0.0

0.0

0.0

~3.0

~5.6

~2.4

Q22

7.5

0.0

7.5

6.9

~7.0

7.5

Q24

0.0

4.5

GND

0.0

0.0

GND

Q25

0.7

4.0

GND

0.0

0.0

GND

Q26

-

-

-

0.0

0.0

0.0

Q27

0.7

NOISE

GND

0.0

0.0

GND

Q33

7.2

4.0

7.5

6.9

7.5

7.5

Q34

0.0

6.6

GND

2.0

0.0

GND

zNOTE: Q9, 10, 15, 19, 20, 23 and 28 - 32 are not fitted on this model series.

zNOTE: ~ indicates approximate voltage. Actual voltage may vary.

Page -26-

May 2001

Page 29
Image 29
Midland Radio SP-300 service manual Voltage Charts, Main Circuit