Operation

Operation

Turning on the fan

^Press the On/Off button.

The fan runs at power level "2". The On/Off indicator lights.

Selecting the power level

^Use the _buttons to select the desired power level.

&=increases the fan speed $=decreases the fan speed

Level "1" to "3" (green indicators) are usually sufficient for normal cooking.

Intensive setting

Level "4" (yellow indicator) should be used for a short period when frying or cooking food with a strong aroma.

Fan performance

The maximum air flow capacity is

625 cfm. Factors such as narrow duct diameter and bends will affect this value.

Level 1 operates at 40% capacity Level 2 operates at 60% capacity Level 3 operates at 80% capacity Level 4 operates at 100% capacity

Delayed Shut Down

If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes.

^Press the Delayed Shut Down button while the fan is still running.

Press once =

5 minute delay

 

(left indicator lights)

Press twice =

15 minute delay

 

(right indicator lights)

To cancel the Delayed Shut Down feature press the button again.