Air extraction

Reducing Collar

(optional accessory)

If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed.

It reduces the air flow to less than 400 CFM.

Check local building codes for max. CFM requirements.

￿Push the Reducing Collar on the exhaust port of the fan.

￿Push the exhaust hose over it.

￿Fix both with a hose clamp.

Condensate trap

(optional accessory)

In some cases, a condensate trap may also be required to collect and evaporate any condensate which may occur. This optional accessory is available for ducts 5" (125 mm) and 6" (150 mm) in diameter.

When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the exhaust outlet.