ATO LOGIC
The C 272 amplifier may be turned on in any one of three discrete ways for complete system flexibility: From the
ATO LOGIC CHART
SWITCH | Amber LED over | Green | Green | Green |
|
front power switch | SWITCH LED | SENSE LED |
| ||
|
| ||||
VACATION switch set to OFF | OFF | OFF | OFF | OFF |
|
|
|
|
|
|
|
VACATION switch set to ON | Amber | OFF | OFF | OFF |
|
|
|
|
|
|
|
Press front power switch with | Green | ON | OFF | OFF |
|
VACATION switch set to ON |
| ||||
|
|
|
|
| |
|
|
|
|
|
|
Press front power switch with | Amber | OFF | OFF | OFF |
|
VACATION switch set to ON |
| ||||
|
|
|
|
| |
|
|
|
|
|
|
12V TRIGGER | Amber LED over | Green | Green | Green |
|
front power switch | SWITCH LED | SENSE LED |
| ||
|
| ||||
VACATION switch set to OFF | OFF | OFF | OFF | OFF |
|
|
|
|
|
|
|
VACATION switch set to ON | Amber | OFF | OFF | OFF |
|
|
|
|
|
|
|
12 V INPUT TRIGGER = 0V with | Amber | OFF | OFF | OFF |
|
VACATION switch set to ON |
| ||||
|
|
|
|
| |
|
|
|
|
|
|
12V INPUT TRIGGER = 12V with | Green | OFF | ON | OFF |
|
VACATION switch set to ON |
| ||||
|
|
|
|
| |
|
|
|
|
|
|
SLEEP/WAKE | Amber LED over | Green | Green | Green |
|
front power switch | SWITCH LED | SENSE LED |
| ||
|
| ||||
VACATION switch set to OFF | OFF | OFF | OFF | OFF |
|
|
|
|
|
|
|
VACATION switch set to ON | Amber | OFF | OFF | OFF |
|
|
|
|
|
|
|
SLEEP/WAKE SENSE DEFEAT switch |
|
|
|
|
|
set to SENSE DEFEAT with VACATION | Amber | OFF | OFF | OFF |
|
switch set to ON |
|
|
|
|
|
SLEEP/WAKE SENSE DEFEAT switch |
|
|
|
|
|
set to SLEEP/WAKE and any source | Green | OFF | OFF | ON |
|
input greater than 20mV with |
| ||||
|
|
|
|
| |
VACATION switch set to ON |
|
|
|
|
|
|
|
|
|
|
|
GB