HLTER(ONT.oo,.
fiLERDATA
SYSTEM SPECIFICATION AND PERFORMANCE DATA SHEET REFRIGERATOR WATER FILTER CARTRIDGE MODEL 9005
Specifications |
|
Service Flow Rate (maximum) | 0,75 GPM (2 83 L/rain) |
RatedService Life Model9005 (maximum) | 500gaHonst1892liters |
MaximumOperatingTemperature | 100° Ft38° C |
MinimumOperatingTemperature | 33° F/1° C |
Minimum PressureRequirement | 35 ps[1138kPa |
MaximumOperatingPressure | 120 psif827kPa |
PERFORMANCE DATA
GENERAL USE
CONDITIONS
Read this PerformanceData Sheet and comparethe capabilities of this
refrigeratorwith your actualwater treatmentneeds
DO NOT use this product where water is microbiologically unsafe or of
unknownquality without adequate disinfectioninstalled beforeor after
filtration system, Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Substance | Influent Challenge | Effluent | Average % | Maximum | Mira Required | Inlet |
Concentration | Average | Reduction | Effluent | Redaction | pH | |
Lead | & 15 mg/L +/.- 19% | 0.001 mg/L | 99.33% | 0,001 mgiL | 0+0t0 mg/L | 6.5 |
Lead | 0.15 rag&.+k 10% | ,0,002 mgiL | 98.66% | 0.003 mgfL | 0.010 mgtL | &5 |
Cyst | Minimum50,O001L | lcount/mL | 99.99% | 3 coanUmL | > 99,95% | NA |
Turbidity | 11+hl NTU | &i2 NTU | 98.98% | O.18NTU | 0.5 NTU | NA |
Lindane | 0.002 rag& +!- t0% | ,0,00005mg/L | 97.62% | 0.00005 mgiL | 0.00002 mgiL | NA |
|
| |||||
Atrazine | 0+009mgiL +/- 10% | 0.0002 mg/L | 97.93% | &0006 mgtL | 0.003 mg/L | NA |
Chlorine | 2.0 mglL +/- 10% | 0+09rng/L | 95.26% | 0.17 mg/L | _75% | NA |
Particulate" | at least 10.000 | 900 cauntimL | 99 68% | 2400 ceanttmL | _85% | NA |
| paFff,c!es/mL |
|
|
|
|
|
0.210 mgiL +/- 10% | 45,45 ugtL | 84.42% | 100 ugiL | 0.0017 mg/L | NA | |
|
| |||||
Asbestos | 1,0'1o10'rLbersfL;t;bersgteater016 MFUmL | 99 96% | 015 MFUmL | 99% | NA | |
| than10mi_motetsmlength |
|
|
|
|
|
";" Tesied Usinga flow rate of 0 75 GPM (2 83 L!rain ) and a maximum pressureof 120 psi (827 kPa) undo+"standard laboratoryconditions, however, actual performance may vav] HealthClaim Performancetested and certified by NSF International
"° Particte size range ctassificationof test+Parttcles used were 0:5+t microns:
Water i'rcaltn_nl D_vic_
Certificate Number
ol + 1486
Use only with cold water supply. Check for compliance with the state and local laws and regulations,
The retractable waterfiLh'ationsystem uses a 9005 replacementcartridge(see Sears contactinformation at the backof yout Use and Care Guideto order) Timely replacementof filter cartridgeis essential for performancesatisfaction from this filtration system+Pleaserefer to the applicable sectionin this Useand Care Guidefor genera! operation, maintenance requirementsand troubleshooting.
This system has been testedaccording to ANSI/NSF 42 and 53for reductionof the substanceslistedbelow,The concentrationof the indicated
substancesin water enteringthe system was reduced to a concentrationlessthan
or equal to the permissiblelimitfor water
leavingthe system,as specifiedin ANSItNSF42 and 53+
@Tesled and codifiedby NSF internationalagainst ANSI/NSF Standards 42 and 53 in modelsWF50+KNI3Ogand
Standard No 42: Aesthetic t_ffeata Standard No, 53: Health Effects
Taste and Odor Reduction | Chemical Redaction Unit |
|
Chledne Reduction | [ Lead, A{razJne,Lindane and 2 | |
Mechanical FiltrationUnit | Mechanical Filtration Unit | " |
Purlieu]ate Reduc ionClass 1 | Cyst, Turbidity and Asbestos Redaction |
@
PentaPure
1000ApolloRoad
Eagan,MinnesotaUS+A
]4