Water filter
Performance Data Sheet For Filter Model 07134220
Using Replacement Cartridge 07134220
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
System tested and certified by NSF International in Model 07134220 against NSF/ANSI Standard 53 for the reduction of Cysts and Turbidity and against Standard 42 for the reduction of Chlorine Taste and Odor; Nominal Particulate Class I.
To a capacity of 739.68 gallons (2800 liters).
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Substance | Average | Influent Challenge | Product | Average | Maximum Permissible | Max. | Min. % | NSF |
| Influent | Concentration | Water | % | Product Water | Effluent | Reduction | Test |
| Concentration | mg/L | Concentration | Reduction | Concentration |
|
|
|
Cysts* | 166500 | Minimum 50,000/L | 1 | 99.99 | 99.95 | 1 | 99.99 | |
Turbidity | 10.7 | 11 + 1 NTU | 0.31 | 97.09 | 0.5 NTU | 0.49 | 95.42 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Particulate |
|
|
|
|
|
|
|
|
Class I Particle size: |
| At least 10,000 |
|
|
|
|
|
|
> 0.5 to < 1 um | 5700000 | particles/ml | 30583 | 99.52 | > 85% | 69000 | 98.9 | |
|
|
|
|
|
|
|
|
|
Chlorine taste |
|
|
|
|
|
|
|
|
and odor | 1.9 | 2.0 mg/L ± 10% | 0.05 | 97.3 | > 50% | 0.06 | 96.84 |
* Based on the use of Cryptosporium parvum oocysts
Application Guidelines/Water Supply Parameters
Water pressure | 30- 120 psi (207 - 827 kPa) |
Water temperature* | 33°F - 100°F (0.6°C - 38°C) |
|
|
Service flow | 0.75 gpm (2.83 lpm) |
IMPORTANT: Must be installed and operated in accordance with application guidelines.
Failure to do so may void warranty. Change filter at least every 6 months.
Flush new cartridge for 3 minutes.
CAUTION: To avoid property damage due to water leakage, you MUST read and follow these operating instructions before installation and use of this product.
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
NSF is a registered trademark of NSF International. CUNO is a trademark of 3M Company used under license. © 2007 3M Company. All rights reserved.
For estimated costs of replacement elements please visit your local appliance dealer or parts distributor.
34