Miele KF 1801 Vi, KF 1911 Vi, KF 1901 Vi, KF 1811 Vi installation instructions Plumbing

Models: KF 1811 Vi KF 1901 Vi KF 1801 Vi KF 1911 Vi

1 84
Download 84 pages 4.2 Kb
Page 77
Image 77
Plumbing

Plumbing

All plumbing work should be carried out by a suitably qualified and competent person, in accordance with all applicable local and national regulations.

The water quality must conform to country requirements for drinking water.

The appliance is only suitable for connection to the cold water supply.

The water pressure must be between 25 and 120 psi (1.72-8.25 bar).

A separate shut-off valve must be installed, so that the water supply can be interrupted as needed.

The maximum outer diameter of the

water pipe (without fittings): 3/8" (10 mm).

The shut-off valve for the water connection must not be located behind the appliance. It is recommended to place the shut-off valve directly next to the appliance (base unit) or in another easily accessible location.

77

Page 77
Image 77
Miele KF 1801 Vi, KF 1911 Vi, KF 1901 Vi, KF 1811 Vi installation instructions Plumbing