Miele KF 7544 Problem solving guide, the floor of the refrigerator sec- tion is wet

Models: KF 7544

1 44
Download 44 pages 55.08 Kb
Page 32
Image 32
.. . the floor of the refrigerator sec- tion is wet.

Problem solving guide

.. . the super freeze or super cool in- dicator light is not lit up although the appliance is working.

The indicator light is defective. Call the Miele Service Department.

.. . the appliance will not switch off or the temperature cannot be adjusted.

The safety lock has been activated.

.. . the interior light in the refrigerator section is not working.

^Was the refrigerator section door left open for too long? The lighting switches itself off automatically after approx. 15 minutes.

If this is not the case, then the bulb is defective:

^Disconnect the appliance from the mains. Switch off at the wall and with- draw the plug from the socket (pull by the plug not the cable), or discon- nect the mains fuse or remove the screw-out fuse in countries where this is applicable.

^Press the sides of the lamp cover in- wards, disengage the cover and unclip it at the rear.

^Unscrew the bulb and replace it with a new one.

Bulb specification:

220 – 240 V, max. 25 W, E 14 fitting

^Screw the new bulb into the connec- tion. Ensure it goes in correctly.

^Replace the cover by clipping it in at the rear and then pressing it in at the sides.

.. . the floor of the refrigerator sec- tion is wet.

The drain hole is blocked.

^Clean the condensate channel and drain hole.

If you still cannot remedy the fault having followed these suggestions, then contact the Miele Service De- partment.

To prevent unecessary loss of tem- perature it is advisable not to open the doors while waiting for the appli- ance to be serviced.