Installation

Installation

Do not place any appliance which gives off heat, such as a toaster or microwave oven, on top of this appliance, as this would increase the appliance's energy consumption.

Location

The appliance should be installed in a dry, well-ventilated room.

The room temperature should not go above or below the climate range for which the appliance is designed. The higher the ambient temperature of the room, the more energy the appliance requires to operate.

It should not be installed where it is exposed to direct sunlight or directly adjacent to a heat-producing appliance such as an oven or a radiator.

Climate range

The climate range of the appliance is stated on the data plate inside the appliance.

Climate range

Ambient room

 

temperature

 

 

SN

+10°C to +32°C

N

+16°C to +32°C

ST

+18°C to +38°C

T

+18°C to +43°C

 

 

This appliance can operate in a wider room temperature range than indicated by the climate range. A constant temperature will be maintained in the appliance at an ambient room temperature of 8 to 43 °C. It is important that the room temperature should be kept within this range.

Ventilation

The appliance can be placed directly against a wall. To ensure sufficient ventilation, the ventilation gaps must not be covered over. The air inlet and outlet must not be covered or blocked in any way. They should be dusted on a regular basis.

Installation

^Remove any cable clips from the back of the appliance.

^Check that all parts at the back of the appliance are unhindered. Remove any hindrance.

^Carefully push the appliance into position.

Aligning the appliance