![](/images/new-backgrounds/1240946/24094631x1.webp)
SECTION 4 − INSTALLATION
Specifications |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Amperes Input at Rated | Amperes Input at Rated |
|
| ||||
Model | Rated Welding | Amperage/Voltage | Max | Load Output, | Load Output, |
|
| ||||
60 Hz, | 50 Hz, |
|
| ||||||||
Output | Range DC | OCV−DC |
|
| |||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
| 230 V | 460 V | 575 V | 380 V | 400 V | 440 V | KVA | KW |
|
|
|
|
|
|
|
|
|
|
|
|
| 1000 A @ 44 | 100 − 1250 A In CC |
| 180 | 90 | 72 |
|
|
| 73 | 53 |
1000 | Mode |
|
|
|
| ||||||
Volts DC, 100% |
| 66 VDC | 5.8* | 2.9* | 2.4* |
|
|
| 3.2* | 0.5* | |
Amp | 10 − 60 V In CV |
|
|
| |||||||
Duty Cycle |
|
|
|
|
|
|
|
|
| ||
|
| Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 900 A @ 44 | 100 − 1250 A In CC |
|
|
|
| 101 | 96 | 87 | 66.3 | 48.4 |
1250 | Mode |
|
|
|
| ||||||
Volts DC, 100% |
| 66 VDC |
|
|
| 5.2* | 5.0* | 4.5* | 3.4* | 0.56* | |
Amp | 10 − 60 V In CV |
|
|
| |||||||
Duty Cycle |
|
|
|
|
|
|
|
|
| ||
|
| Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*While idling |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 2000 |
|
|
|
|
|
|
| Duty Cycle is percentage of 10 min- | |||
|
|
|
|
|
|
|
| utes that unit can weld at rated load | ||||
| 1800 |
|
|
|
|
|
|
| ||||
| 1600 |
|
|
|
|
|
|
| without overheating. |
|
| |
| 1400 |
|
|
|
|
| DIMENSION 1000 | If unit overheats, thermostat(s) | ||||
| 1200 |
|
|
|
|
| opens, output stops, and cooling | |||||
|
|
|
|
|
|
|
| |||||
| 1000 |
|
|
| DIMENSION 1250 |
|
| fan runs. Wait fifteen minutes for | ||||
WELD |
|
|
|
|
|
|
| unit to cool. Reduce amperage or | ||||
|
|
|
|
|
|
|
| |||||
800 |
|
|
|
|
|
|
| duty cycle before welding. |
| |||
|
|
|
|
|
|
|
|
| ||||
| 700 |
|
|
|
|
|
|
| Y Exceeding duty | cycle | can | |
AMPERES |
|
|
|
|
|
|
| damage | unit | and | void | |
|
|
|
|
|
|
|
| warranty. |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| 600 |
|
|
|
|
|
|
|
|
|
|
|
| 500 |
|
|
|
|
|
|
|
|
|
|
|
| 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 90 100 |
|
|
| |
|
|
| % DUTY CYCLE |
|
|
|
|
|
|
| ||
|
|
| 100% Duty Cycle |
|
|
|
|
|
|
|
| |
|
|
| Continuous Welding |
|
|
|
|
|
|
|
| |
Overheating |
|
| 0 |
|
|
|
|
| A/V |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OR |
|
|
|
|
|
|
| Minutes |
|
| Reduce Duty Cycle |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| duty1 4/95 / | ||
|
|
|
|
|
|
|
|
|
|
|
|