3-4. Installing Gas Supply

1

Argon Gas

OR

2 3

CO2 Gas

Chain gas cylinder to running gear, wall, or other stationary support so cylinder cannot fall and break off valve.

1Regulator/Flow Gauge Install so face is vertical.

2Gas Hose Connection

3Flow Adjust

Typical flow rate is 0.9 liters per minute. Check wire manufactur- er’s recommended flow rate. This flow gauge can be adjusted be- tween 2.36 and 11.8 liters per min- ute.

Ref. ST-148 265-B / Ref. ST-149 827-B / Ref. ST-158 697-A

3-5. Installing Wire Spool and Adjusting Hub Tension

When a slight force is needed to turn spool, tension is set.

Tools Needed:

Nov. 16, 2005

OM-223 194 Page 10

Page 14
Image 14
Miller Electric 273, 271, 383, 293, 333 manual Installing Gas Supply, Installing Wire Spool and Adjusting Hub Tension