3-3. Connecting Spool Gun To Millermatic 210

4

3

5

6

Rear

Panel

 

 

1

Barbed Fitting

 

 

1

2

. If spool gun

gas

hose is

 

 

equipped with a pre-installed

 

 

 

 

 

 

barbed fitting, cut off fitting from

 

 

 

end of hose.

 

 

 

 

Connect spool gun gas hose to

 

 

barbed fitting.

 

 

 

 

2

Gun Trigger Plug

 

 

 

Insert plug into receptacle labeled

 

 

“SPOOL

GUN”,

and

tighten

 

 

threaded collar.

 

 

 

 

3

Negative (−) Output Terminal

 

 

4

Positive (+) Output Terminal

 

 

Connect spool gun weld cable to

 

 

positive (+) output terminal.

 

 

Close door.

 

 

 

 

5

Welding Power Source Gas

 

 

 

Hose Connection For Spool

 

 

 

Gun

 

 

 

 

 

6

Welding Power Source Gas

 

 

 

Hose Connection For MIG

 

 

 

Gun

 

 

 

 

 

Connect

gas hose

between

 

 

regulator/flowmeter

gas hose

 

 

connection, and fitting on rear of

 

 

welding power source.

 

802 998-C

OM-1216 Page 10