4-7. Connecting Work Clamp

1

2

1Work Clamp

2Workpiece

Connect work clamp to a clean, paint-free location on workpiece, as close to cutting area as possible.

802 463-A

4-8. Connecting Input Power

1

2

Check input voltage available at site. 1 Changeover Switch

Switch is accessible through slot in rear panel.

2 Changeover Switch Label

Look at label to find correct switch position.

YBe sure input power connection meets all applicable national, regional, and local electrical codes.

3Grounded 120 VAC Receptacle

Y To use rated output (see spec-

ifications), connect the unit to

an individual branch circuit

capable of carrying the effec-

tive (eff) current for the output

being used. The unit must

have a properly sized plug

3

4

installed and the circuit must

be protected by properly

sized fuses or circuit break-

ers.

A 120 volt, 20 ampere (minimum) individual branch circuit protected by time-delay fuses or circuit breaker is required (see Section 4-1).

4Plug From Unit Connect plug to receptacle.

If an extension cord is necessary, select a cord of 12 AWG for up to 53 ft (16 m).

To connect unit to 230 VAC input power, a customer supplied plug is necessary (see Section 4-9).

A 230 volt, 15 ampere (minimum) individual branch circuit protected by time-delay fuses or circuit breaker is required (see Section 4-1).

If an extension cord is necessary, select a cord of 14 AWG for up to 133 ft (41 m).

YSpecial installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20.

Ref. 802 787-B / 802 786-B

OM-2229 Page 15

Page 19
Image 19
Miller Electric ICE-27C, 375 manual Connecting Work Clamp, Connecting Input Power