6-4. Checking/Replacing Retaining Cup, Tip, And Electrode

Overtightening will strip threads. Do not overtighten retaining cup during assembly. Do not cross-thread parts causing stripping. Use care during torch assembly and parts replacement.

Inspect shield cup, tip, and electrode for wear before cutting or whenever cutting speed has been significantly reduced. Do not operate torch without a tip or electrode in place. Be sure to use genuine replacement parts.

A good practice is to replace both the tip and electrode at the same time.

Turn Off power source before checking torch parts.

Make sure this area is clean of any debris.

7

6

Make sure swirl ring is clean of any debris and no holes are obstructed.

4

3

1

New

2

 

5

New

1/16 in (2 mm)

Pit

Worn

Worn

Turn Off power source.

1Shield Cup

2O-Ring

Remove shield cup. Check cup for cracks, and replace if necessary.

Check O-ring for cracks or worn spots, re- place shield cup if necessary.

3 Tip

4 Opening

Remove tip. Check tip, and replace if open- ing is deformed or 50% oversize. If inside of tip is not clean and bright, clean with steel wool. Be sure to remove any pieces of steel wool afterwards.

5 Electrode

Check electrode. If center has a pit more

802 465

than a 1/16 in (2 mm) deep, remove and re- place electrode.

6 Swirl Ring

Remove swirl ring. Check ring, and replace if side holes are plugged.

7 O-Ring

Check O-ring for cracks or worn spots, and replace if necessary.

Carefully reassemble parts in reverse order.

OM-2229 Page 23

Page 27
Image 27
Miller Electric ICE-27C, 375 manual Checking/Replacing Retaining Cup, Tip, And Electrode