OPERATION | ||
|
|
|
•Selection of “hot” or “cold” output terminals with a tog- gle switch on the control panel. This feature can also be controlled by installing a remote output terminal control cable designed to open and close the #2 and #4 leads in the amphenol receptacle.
FOR AUXILIARY POWER
•10,000 watts of 120/240 VAC, 60Hz auxiliary power.
•Drive a 2 HP motor (provided it is started under no load).
•Two 15 amp 120 VAC duplex receptacles with GFCI protection for up to 30 amps of 120 VAC power.
•One 50 amp, 120/240 VAC dual voltage receptacle for up to 44 amps of 240 VAC, and up to 44 amps per side to separate branch circuits (not in parallel) of 120 VAC single phase auxiliary power. Allows easy con- nection to premises wiring.
•Weld and AC auxiliary power at the same time (with- in machine total capacity).
OTHER FEATURES
•Deutz
•Engine protection system shuts the engine down for low oil pressure, high oil temperature or a broken fan/engine alternator belt.
•Gauges for oil pressure, oil temperature, engine alter- nator output and fuel level.
•Indicator lights for low oil pressure, high oil tempera- ture, engine alternator low output/broken belt and low fuel level.
•Automatic low fuel shutdown before running out of fuel.
•Engine hour meter standard on all models.
•Extended range 25 gallon (94.6 l) fuel tank.
•Fuel
•Automatic idler reduces engine speed when not weld- ing or drawing auxiliary power. This feature reduces fuel consumption and extends engine life.
•Single side engine service with over the top access to the engine.
•Copper alternator windings and high temperature insulation for dependability and long life.
ADDITIONAL DESIGN FEATURES AND
ADVANTAGES (Stick & Wire Model only)
FOR WIRE WELDING
•One constant voltage position for all wire welding. A 12 to 45V range across the entire current output range.
•Excellent arc characteristics with MIG (GMAW) and Innershield (FCAW) welding.
•A Wire Feeder connector for quick connection of the control cable.
•A built in “Electronic Contactor” for “Cold” electrode when not welding. This feature and DC Constant Voltage output provide an added margin of safety when welding must be performed under electrically hazardous conditions such as: damp locations, while wearing wet clothing or in cramped positions if there is a high risk of unavoidable or accidental contact with the workpiece or ground.
•The 3 digit display has the additional feature of pre- setting the open circuit voltage and displaying the actual voltage during welding.
•Designed for use with the following Lincoln wire feeders.
•Spool Gun & | ||
|
| K488 Module |
WELDING CAPABILITY
The Commander 400 is rated at 400 amps, 40 volts at 100% duty cycle. The weld current is variable from 40 to 575 amps.
COMMANDER 400 | MAY96 |